Installing Hot-Swap Hard Disk Drives; Replacing Hot-Swap Hard Disk Drives; Locking The Drive In Place - IBM DCS3860 Installation, User's, And Maintenance Manual

Hide thumbs Also See for DCS3860:
Table of Contents

Advertisement

Release
latch
Figure 48. Locking the drive in place
7. Push the drive drawer all the way back into the storage expansion enclosure,
8. Install the bezel on the front of the storage expansion enclosure. See "Replacing

Installing hot-swap hard disk drives

With the exception of the DCS3860 storage system initial power on, you should
add DDMs while the storage expansion enclosure is turned on and running.
Attention: After you remove a DDM FRU, wait for 90 seconds before replacing or
reseating it to allow it to properly spin down.

Replacing hot-swap hard disk drives

Problems with DDMs include any malfunctions that delay, interrupt, or prevent
successful I/O activity between the hosts and the DDMs in the storage expansion
enclosure. This includes transmission problems between the controllers, the ESMs,
and the DDMs. This section contains instructions to replace a failed DDM.
Note: If you want to remove a DDM that is not in a failed or bypass state, use the
IBM DS Storage Manager client program either to place the DDM in a failed state
or to place the array that is associated with the DDM (or DDMs) in an offline state
before you remove it from the enclosure.
Attention: Failure to replace the DDMs in their correct drawer and position
might result in loss of data. If you are replacing a DDM that is part of a configured
array and logical drive, ensure that you install the replacement DDM in the correct
drawer and position.
Before you begin, ensure that you wear an anti-static wrist strap.
Complete the following steps to replace a hot-swap DDM:
92
IBM System Storage DCS3860 Storage System: Installation, User's, and Maintenance Guide
92.
Drive
handle
closing the levers on each side of the drive drawer.
the bezel" on page 106 for the steps to install the bezel.
1. Use the Storage Management client software to print a new storage system
profile.
2. Determine the location of the DDM that you want to remove.
Attention: Never hot-swap an DDM FRU when its associated green activity
LED is flashing. Hot-swap an DDM FRU only when its associated blue Service
Action Allowed LED is lit.