Panasonic PT-RZ670 series Command Manual page 200

Hide thumbs Also See for PT-RZ670 series:
Table of Contents

Advertisement

Unused
35
34
Exhaust air temperature sensor disconnected
Optical module temperature sensor
33
disconnected
32
Intake air temperature sensor disconnected
31
Luminance sensor error
30
Unused
29
Unused
28
Low AC voltage warning
27
PW2 error (FPGA)
26
PW2 error (FM)
25
PW1 error (FPGA)
24
PW1 error (FM)
23
AC7
22
AC6
21
AC5
20
AC4
19
AC3
18
AC2
17
AC1
16
AC0
15
AA7
14
AA6
13
AA5
12
AA4
11
AA3
10
AA2
9
AA1
8
AA0
7
Optical module low temperature error
6
Exhaust air high temperature error
5
Optical module high temperature error
4
Intake air temperature error
3
Optical module low temperature warning
2
Exhaust air high temperature warning
1
Optical module high temperature warning
0
Intake air temperature warning
Unused
Exhaust air thermosensor has breaking of wire, or connector (M11/BR4) is
disconnected.
DMD thermosensor has breaking of wire, or connector (DG4/FM2) is disconnected.
Intake air thermosensor has breaking of wire, or connector (M11/DG18) is
disconnected.
Luminance sensor proportion is abnormal.
Luminance is abnormal.
Low AC voltage.
Phosphor1 wheel or circuit are failure.
Phosphor2 wheel or circuit are failure.
Internal Warning.
The temperature inside this projector has become high or ambient
temperature is too low.
- The ventilation holes may be closed.
- The ambient temperature in the place of use may
be too high or low.
- Heatsink mounting is abnormal
- High altitude mode is mis select