Milwaukee DL100 Operation Manual
Milwaukee DL100 Operation Manual

Milwaukee DL100 Operation Manual

Data logging monitor ph/temperature

Advertisement

Quick Links

DL100 BLACK BOX
DATA LOGGING MONITOR
pH/Temperature
Set Up / Operation Manual
1

Advertisement

loading

Summary of Contents for Milwaukee DL100

  • Page 1 DL100 BLACK BOX DATA LOGGING MONITOR pH/Temperature Set Up / Operation Manual...
  • Page 2 DL100 MENU MAP **Menu** > Basic Setup Data Log Setup Last Logged Wi-Fi Settings Exit **Basic Setup** **Basic Setup** **Basic Setup** > Date & Time Date & Time Date & Time Temperature > Temperature Temperature pH Resolution pH Resolution > pH Resolution...
  • Page 3 Once you have connected all the cords, inserted the SD card, and The Lights button allows you to turn off the screen and status plugged the DL100 into a wall socket, please read this section, lights (lights to the left and right of screen, behind grills). The taking a few moments to learn about the screen and keypad.
  • Page 4 Please be sure to read Getting to Know the DL100, previous page, before beginning Basic Setup. Getting Started with Basic Setup Note that this unit displays in military time (24-hour); there is no am/pm option, that is, 9AM is 09:00 and 2:05PM is 14:05.
  • Page 5: Setting Calibration Points

    You want to receive the alerts • Once the probe has calibrated in the 4.01 solution, when needed, but you don’t want the DL100 to be sending out calibration is complete. alerts too frequently. See the diagram below for a typical setup.
  • Page 6: Setting Manual Temperature Compensation

    (except for Snap Shots); however, beside each are the desired settings, you may “Exit” the screen. Milwaukee Instruments recommends a wider interval, 2) If you want to change the Caution setting, place the cursor typically 00:10:00 to 00:15:00. For most applications, this 10- to beside “pH Caution”...
  • Page 7 This screen will show upload interval, that is, how often the Disabled mode. Enable Wi-Fi as the last step, otherwise the unit DL100 sends new information to the portal. Five minutes is the may begin uploading information before you finish entering it.
  • Page 8 DL100 BLACK BOX SPECIFICATIONS Range .001 pH to 14.000 pH Resolution - User Select Tenths (0.1 pH); Hundredths (0.01 pH); Thousandths (0.001) pH Accuracy @ 77°F 0.02 pH Setpoint Range 0.01 pH to 14.00 pH Activation Parameter User Select above or below activation setpoint Visual Alerts LED backlight blue = normal;...