Panasonic EYFLA1A Operating Instructions Manual page 11

Cordless impact driver / cordless impact wrench
Hide thumbs Also See for EYFLA1A:
Table of Contents

Advertisement

Available languages

Available languages

• You can select from 30 torque clutch
settings (1 to 30).
• Use figures from the Tightening Torque
Chart to guide your selection of torque
clutch setting. (See the following tighten-
ing torque chart)
. Press the OK button to accept the select-
ed torque clutch setting.
• The control panel will stop flashing and
light up.
CAUTION:
• You must press the OK button in order
for the selected setting to take effect.
• Be sure to verify the new value after
changing the setting. (See page 11.)
Tightening Torque Chart (for Reference
Use)
The values illustrated on this chart were mea-
sured under the conditions described below
and are provided for reference purposes.
Actual tightening torque varies with ambient
conditions (the particular bolt being tightened,
hardware being used, method of holding the
bolt in place, etc.).
N • m
60
50
40
30
EYFLA3 (M8)
20
EYFLA2 (M6)
10
0
1 2 3 4 5 6 7 8 9 10 111213 1415 16171819202122 232425 26272829 30
Measurement conditions
• Temperature: Room temperature (0°C/68°F)
Using the Interval Set
• The interval set operates to prevent the tool
from operating after it automatically stops as
a result of the torque control function, even if
the switch is engaged.
1. Set the tool to configuration mode.
(See page 10.)
. Press the interval set button.
• The control panel will begin flashing.
Display: The number 0 flashes on and off.
Battery indication lamp: The middle bar
of the battery flashes on and off.
EYFLA3 (M10)
EYFLA2 (M8)
EYFLA1 (M8)
EYFLA1 (M6)
Display
3. Press the
desired time.
Buttons
4. Press the OK button to accept the select-
ed setting.
• The control panel will stop flashing and
light up, and the torque clutch setting
will be displayed.
CAUTION:
• Be sure to verify the new value after
changing the setting.
Initializing All Settings
Factory settings
• Torque clutch setting: "F" (torque con-
trol function off)
• Interval setting: 0 (off)
• This section explains how to revert all tool
settings to their default values at the time of
shipment from the factory.
• The error display will be turned off.
1. Set the tool to configuration mode.
(See page 10.)
. Press the format button.
• The control panel will begin flashing.
Display: The letter "F" flashes on and off.
Battery indication lamp: The upper and
lower bars of the battery flash on and off.
Display
- 11 -
Battery indication lamp
and
buttons to set the
Display
Seconds
30
1
0
Battery indication lamp
3
0.1
Off

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eyfla2qEyfla3jEyfla2a

Table of Contents