Fitting procedure

1. Confirm the strength of the proposed fitting location
The weight of the wall-hanging bracket is approximately 10 kg. The plasma TV unit attached
to the wall-hanging bracket weighs approximately 34.5 to 56 kg.
Check the wall strength at the 6 attachment locations by referring to the dimension drawing
of the wall-hanging bracket ( given at right ) , and provide adequate reinforcement if strength
is not sufficient.
Note
• There are 14 holes in the wall-hanging
bracket.
If the wall material is wood, and adequate
attachment strength cannot be ensured
by fastening at the 6 points at right, use
as many spare holes as necessary.
However, exercise care because some
wall materials may crack if screws are
located too close together.
* For detailed dimensions for attaching the
plasma TV, refer to the separate External
Dimension Drawing (page38 -39).
2. Fit wall-hanging bracket to wall
• Fit so that the arrow marks on the wall-hanging bracket point upward.
• If the wall consists of a material such as concrete and bolts or nuts must
be embedded beforehand, determine the hole positions by aligning using
the actual wall-hanging bracket, or calculate hole positions based on the
dimension drawing, and then embed "M6" bolts or nuts. When
embedding bolts, locate so that the bolts protrude from the wall by 10 to
15 mm.
( 1 ) Fasten the screw at the top center hole first.
( 2 ) Using a level, correct any bracket inclination, and then fasten
screws at the remaining 5 locations.
• Use commercially available M6 screws suited to the wall surface material ( wood,
Note
steel frame, concrete etc. ) for fitting the bracket to the wall.
3. Angle adjustment of wall-hanging bracket
The angle of the wall-hanging bracket can be adjusted from "no incline"
to "20° incline" in 5 settings at intervals of 5°
( The TH-50PV30E, TH-50PV30B has 4 settings, ranging up to "15°
incline." )
The bracket is set to 5° before shipment from the factory.
To change the angle, move the attachment position of the strap.
* The strap is not needed for the "no incline" setting.
Angle adjustment hole positions
4
5° incline
10° incline
15° incline
20° incline
No incline
15
450
* Be sure to fit screws and tighten securely.
Unit: mm
At 5° incline
930
450
15
Wall attachment
holes (at 6 points)
At 15° incline
No incline
Strap