The Flex System X6 Compute Node, machine type 7903, is a high-performance scalable compute node
that is designed to take on the most demanding workloads. The performance, flexibility, and resiliency
features enable the X6 to run mission-critical workloads, such as key business applications, database,
analytics, and large virtual machine deployments.
The X6 Compute Node family is composed of the x880 X6, x480 X6, and x280 X6. Each compute node
contains two Intel Xeon E7 processors. The x880 X6 uses E7-8800 v2 processors and supports joining
two or four x880 compute nodes together to form a single 8-socket server with 192 DIMM slots. The x480
uses E7-4800 v2 processors and supports joining two x480 compute nodes together to form a single
4-socket server with 96 DIMM slots. The x280 has two E7-2800 v2 processors and 48 DIMM slots but
does not offer scaling.
Suggested use : Mission-critical scalable databases, business analytics, virtualization, enterprise
applications, and cloud applications.
Figure 1 shows the Flex System X6 Compute Node.
Figure 1. Flex System X6 Compute Node
Did you know?
If you are using an application that requires significant computing power and you value the integration of
components that Flex System offers, then the X6 Compute Node family is an excellent choice. It offers
the performance and reliability of the Intel Xeon E7 processor family, plus significant memory and I/O
capacity, and lets you easily scale from two sockets all the way to eight sockets by simply adding more
compute nodes and using the appropriate scalability connector on the front of the server.
Flex System X6 Compute Node (7903)
1

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo Flex System X6 Compute Node

  • Page 1 Flex System X6 Compute Node (7903) Lenovo Press Product Guide The Flex System X6 Compute Node, machine type 7903, is a high-performance scalable compute node that is designed to take on the most demanding workloads. The performance, flexibility, and resiliency features enable the X6 to run mission-critical workloads, such as key business applications, database, analytics, and large virtual machine deployments.
  • Page 2: Key Features

    Clients are looking for cost-optimized and fit-for-purpose IT solutions that manage large amounts of data, easily scale performance, and provide enterprise class reliability. Built on decades of innovation, Lenovo introduces its sixth generation of Enterprise X-Architecture® technology into the Flex System ecosystem with the announcement of the Flex System X6 family of compute nodes.
  • Page 3 Redundant Intel Platform Controller Hub (PCH) connections to the processors allow the platform to  maintain access to networking, storage, and server management during a processor failure. Hot-swap drives support RAID redundancy for data protection and greater system uptime.  Flex System X6 Compute Node (7903)
  • Page 4 Built-in diagnostic tests, using Dynamic Systems Analysis (DSA) Preboot, speed up troubleshooting  tasks to reduce service time. Three-year customer-replaceable unit and onsite limited warranty, 9x5 next business day. Optional  service upgrades are available. Flex System X6 Compute Node (7903)
  • Page 5: Locations Of Key Components And Connectors

    Locations of key components and connectors Figure 2 shows the front of the server and Figure 3 shows the inside of the server. Figure 2. Front view of the Flex System X6 Compute Node Figure 3. Inside view of the Flex System X6 Compute Node...
  • Page 6 8-socket complex. Note this is for illustrative purposes only; in a production environment, you first install the compute nodes in the chassis and then attach the scalability connector to all four nodes. Figure 4. Four x880 X6 Compute Nodes in an 8-socket complex Flex System X6 Compute Node (7903)
  • Page 7: Standard Specifications

    ECC, Chipkill (for x4-based memory DIMMs), memory mirroring, and memory rank sparing. protection Memory-chann eXFlash DIMMs not supported. el storage Disk drive bays Standard: Two 2.5-inch hot-swap SAS/SATA drive bays that support SAS, SATA, and SSD drives. Flex System X6 Compute Node (7903)
  • Page 8 UEFI, Integrated Management Module 2 (IMM2) with Renesas SH7757 controller, Predictive management Failure Analysis, light path diagnostics panel, automatic server restart, and remote presence. Support for Lenovo XClarity Administrator, IBM Flex System Manager™, IBM Systems Director, and ServerGuide. Security Power-on password, administrator's password, and Trusted Platform Module V1.2.
  • Page 9: Standard Models

    ** Processor detail: Processor quantity and model, cores, core speed, L3 cache, memory speed, and power consumption. ‡ For models D2x, the standard DIMM is rated at 1600 MHz, but operates at 1333 MHz to match the processor memory speed. Flex System X6 Compute Node (7903)
  • Page 10: Chassis Support

    The power redundancy policy that is used (N+1 or N+N)  The following table provides guidelines about what number of X6 Compute Nodes can be installed. For more information, use the Power Configurator, found at the following website: http://ibm.com/systems/bladecenter/resources/powerconfig.html Flex System X6 Compute Node (7903)
  • Page 11 The processors in 2-socket configurations must be identical. The scaled X6 compute nodes are connected together through a front interconnect system. The interconnection has a QPI bus plus the sideband signals that are needed for correct operation. Flex System X6 Compute Node (7903)
  • Page 12 The following figure shows the Flex System x880 X6 4-Socket Scalability Connector and how it is used to connect two X6 servers together (x880 or x480). Figure 5. Flex System x880 X6 4-Socket Scalability Connector Flex System X6 Compute Node (7903)
  • Page 13: Processor Options

    † The processors support two memory modes: RAS mode (also known as lockstep mode) and Performance mode (also known as independent mode). In Performance mode, the SMI2 link operates at twice the memory bus speed that is shown. Flex System X6 Compute Node (7903)
  • Page 14: Memory Options

    Memory options Lenovo DDR3 memory is compatibility tested and tuned for optimal performance and throughput. Lenovo memory specifications are integrated into the light path diagnostic tests for immediate system performance feedback and optimum system uptime. From a service and support standpoint, Lenovo memory automatically assumes the system warranty.
  • Page 15 3 DIMMs per channel 1066 MHz 1333 MHz 1066 MHz 1333 MHz 1333 MHz 1333 MHz 1333 MHz 1333 MHz * Maximum quantity that is supported is shown for all the processors that are installed. Flex System X6 Compute Node (7903)
  • Page 16: Internal Storage

    ServeRAID M1200 Zero Cache/RAID 5 Upgrade (FOD) Supported drives are listed in the "Internal drive options" section. Note: The X6 Compute Node, machine type 7903, does not support 1.8-inch drives nor the ServeRAID M5115. Flex System X6 Compute Node (7903)
  • Page 17: Internal Drive Options

    A4TV 250GB 7.2K 6Gbps NL SATA 2.5" G3HS HDD 2.5-inch 6Gb NL SAS drives 00AJ086 A4TU 1TB 7.2K 6Gbps NL SAS 2.5'' G3HS HDD 00AJ121 A4TT 500GB 7.2K 6Gbps NL SAS 2.5" G3HS HDD Flex System X6 Compute Node (7903)
  • Page 18 1.8TB 10K 12Gbps SAS 2.5'' G3HS 512e SED 2.5-inch 12Gb SAS 15K hot-swap hybrid HDDs 00NA311 ASBV 300GB 15K 12Gbps SAS 2.5" G3HS 512e Hybrid 00NA321 ASBX 600GB 15K 12Gbps SAS 2.5" G3HS 512e Hybrid Flex System X6 Compute Node (7903)
  • Page 19: Internal Tape Drives

    800GB SED 12G SAS 2.5" MLC G3HS Enterprise SSD Internal tape drives The server does not support an internal tape drive. However, it can be attached to external tape drives by using Fibre Channel connectivity. Flex System X6 Compute Node (7903)
  • Page 20: Optical Drives

    Lenovo. Alternatively, use the remote media feature of the IMMv2 and the Chassis Management Module. Note: The USB port on the compute node supplies up to 0.5 A at 5 V. For devices that require more power, an additional power source is required.
  • Page 21 Slot 4 Port 1 Module bay 3 (Dual-ASIC adapters Port 2 Module bay 4 are not supported.) For a list of supported switches, see the Flex System Interoperability Guide, available from: http://lenovopress.com/fsig Flex System X6 Compute Node (7903)
  • Page 22 Figure 7. Location of the switch bays in the Flex System Enterprise Chassis The following figure shows how 2-port adapters are connected to switches that are installed in the chassis. Figure 8. Logical layout of the interconnects between I/O adapters and I/O modules Flex System X6 Compute Node (7903)
  • Page 23: Network Adapters

    * Adapters with two ASICs are not supported in slots 3 and 4 because of the available PCIe lanes in those slots For adapter-to-switch compatibility, see the Flex System Interoperability Guide: http://lenovopress.com/fsig For more information, see the list of Lenovo Press Product Guides in the Adapter cards category: http://lenovopress.com/flexsystem/adapters Flex System X6 Compute Node (7903)
  • Page 24: Storage Host Bus Adapters

    * Adapters with two ASICs are not supported in slots 3 and 4 because of the available PCIe lanes in those slots. Power supplies Server power is derived from the power supplies that are installed in the chassis. There are no server options regarding power supplies. Flex System X6 Compute Node (7903)
  • Page 25: Integrated Virtualization

    USB Memory Key for VMware ESXi 5.0 Update 1 41Y8311 A2R3 USB Memory Key for VMware ESXi 5.1 41Y8382 A4WZ USB Memory Key for VMware ESXi 5.1 Update 1 41Y8385 A584 USB Memory Key for VMware ESXi 5.5 Flex System X6 Compute Node (7903)
  • Page 26: Light Path Diagnostics Panel

    An over-temperature condition occurred that was critical enough to shut down the server. A memory fault has occurred. The corresponding DIMM error LEDs on the system board are also lit. A fault is detected in the adjacent expansion unit (if installed). Flex System X6 Compute Node (7903)
  • Page 27: Remote Management

    Note: Support by some of these operating system versions will be after the date of initial availability. For the latest information about the specific versions and service levels that are supported and any other prerequisites, see the ServerProven® website at: http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml Flex System X6 Compute Node (7903)
  • Page 28: Physical Specifications

     Maximum weight: 12.25 kg (27 lbs)  Supported environment The Flex System X6 Compute Node complies with ASHRAE Class A3 specifications. This is the supported operating environment: Power on: Temperature: 5 to 40 °C (41 to 104 °F) ...
  • Page 29: Warranty Options

    Warranty options The Flex System X6 Compute Node has a three-year warranty with 24x7 standard call center support and 9x5 Next Business Day onsite coverage. Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
  • Page 30 Lenovo server. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands.
  • Page 31: Regulatory Compliance

    GOST R 51317.3.3 IEC 60950-1 (CB Certificate and CB Test Report)  CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)  CISPR 22, Class A  TUV-GS (EN60950-1/IEC 60950-1 and EK1-ITB2000)  Flex System X6 Compute Node (7903)
  • Page 32: Lenovo Financial Services

    For you, this dedication provides a high-quality, easy, and positive financing experience. For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website: http://www.lenovo.com/services_warranty/us/en/financial_services.html...
  • Page 33: Related Publications And Links

    Flex System x880 X6 product page  http://shop.lenovo.com/us/en/systems/servers/mission-critical/x880/ Flex System Information Center:  http://publib.boulder.ibm.com/infocenter/flexsys/information/index.jsp Flex System X6 Compute Node Installation and Service Guide :  http://publib.boulder.ibm.com/infocenter/flexsys/information/topic/com.ibm.acc.7903.doc/printable_do c.html ServerProven for Flex System:  http://ibm.com/systems/info/x86servers/serverproven/compat/us/flexsystems.html ServerProven compatibility page for operating system support: ...
  • Page 34 Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment.
  • Page 35 Trademarks Lenovo, For Those Who Do and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. These and other Lenovo trademarked terms are marked on their first occurrence in this information with the appropriate symbol (® or ™), indicating US registered or common law trademarks owned by Lenovo at the time this information was published.

Table of Contents