13.4 Tape speed adjustment/(Deck 1/2)
TOP PREVIOUS NEXT
Note:
When connecting the unit to other system components for test, short the section between the test
point
TP604
and
TP609
Deck 1 or Deck 2 indicatorwill blink.)
Normal speed (Standard value: 3000 ± 45 Hz)
1. Connect the measuring instrument as shown in
2. Playback the middle portion of test tape. (QZZCWAT)
3. Adjust
VR801
(Deck 1) and
point, refer to
Fig. 13-11.
Adjustment target: 3000 ± 15 Hz (Normal speed)
Standard value: 3000 ± 45 Hz (Normal speed)
Note:
When the unit is finished for adjusting, disconnect the short section between
@
TOP PREVIOUS NEXT
and turn on the entire system. (The unit is set to the TEST mode, and either
VR803
(Deck 2) for output value shown below. (For adjustment
)
Fig. 13-3.
http://servis-manual.com/
Fig. 13-3.
TP604
and
TP609
.