Gph5d chassis plasma display panel
Table of Contents

Advertisement

Driver Set-up

Item / Preparation
Input an APL 100 % white signal.
Set the picture mode to Normal and the White Balance to Normal
Adjustments
To perform the following adjustments, please refer to the panel information label
located on the heat sink of the panel. See the next page for more information
about the panel label.
Name
Vsus
Vbk
Ve
Vset
Vad
Vda
VSCN
Test point
TPVSUS
(SS-BOARD)
TPVBK
(SC-BOARD)
TPVE
(SS-BOARD)
TPVSET
(SC-BOARD)
TPVAD
(C9-BOARD)
TP117
(SC-BOARD)
TPVSCN
(SC-BOARD)
77
Voltage
Vsus ± 1V*
Vbk ± 5V*
Ve ± 1V*
218 V ± 6V
Vad ± 1V*
74V ± 1V
Vad+118 ± 2V
Volume
R625
(P3-BOARD)
R6670
(SC-BOARD)
R6770
(SS-BOARD)
---
R6477
(SC-BOARD)
R545
(P1-BOARD)
---