Configure Upm Ports As Ethernet Pass-Through (Optional); View The Current Configuration; Configure Port Group 0 As Ethernet Pass-Through - Dell S5000 Configuration Manual

Sc series iscsi sans
Hide thumbs Also See for S5000:
Table of Contents

Advertisement

3

Configure UPM ports as Ethernet pass-through (optional)

The FC ports on the Unified Port Module (UPM) can be configured as Ethernet pass-through. Use this
section only if the UPM module is used. The 12 ports are divided into six port groups numbered 0-5. Two
ports in each port group can be configured separately as FC or Ethernet pass-through.
Note: This operation requires a reload for the changes to take effect.
3.1

View the current configuration

Use this command to view the current mode of the ports and also the port group mapping.
FTOS#
show system
PortGroupId
0
1
2
3
4
5
3.2

Configure port group 0 as Ethernet pass-through

FTOS(conf)# stack-unit 0 port-group 0 portmode Ethernet
Changing port mode on slot 0 port-group 0 will make interface configs of 0 and 1
obsolete after a save and reload.
[confirm yes/no]:yes
Please save and reload for the changes to take effect.
Note: Save and reload is required.
10
SCG2004
Dell Networking S5000 Switch Configuration Guide for SC Series SANs
stack-unit
0 port-group portmode
Ports
Mode(Curr Boot) Mode(Next Boot)
0,1
FC
2,3
FC
4,5
FC
6,7
FC
8,9
FC
10,11
FC
FC
FC
FC
FC
FC
FC

Advertisement

Table of Contents
loading

Table of Contents