GENERAL
This INSTALLATION MANUAL briefly outlines where
and how to install the air conditioning system. Please
read over the entire set of instructions for the indoor
and outdoor units and make sure all accessory parts
listed are with the system before beginning.
1. TYPE OF COPPER PIPE AND INSULATION MATERIAL
Copper tubing for connectin the outdoor unit to the indoor
unit and insulation material is available for purchase locally.
When you purchase them, please specify the following.
A. Deoxidized annealed copper pipe for refrigerant piping as:
Table 3
Small pipe
Outer diameter
Thickness
1/4"(6.35 mm)
1/32"(0.8 mm)
Cut each pipe to the appropriate length +12" (30 cm)
to16" (40 cm) to dampen vibration between units.
B. Foamed polyethylene insulation for copper pipes as
required to precise length of piping. Wall thickness
of the insulation should not be less than 5/16" (8 mm).
C. Use insulated copper wire for field wiring.
CAUTION
Check local electrical codes and regulations
before obtaining wire. Also, check any specified
instructions or limitations.
2. ADDITIONAL MATERIALS REQUIRED FOR INSTALLATION
A. Refrigeration (armored) tape
B. Insulated staples or clamps for connecting wire
(See your local electrical codes.)
C. Putty
D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping

3. OPERATING RANGE

Table 4
Cooling/Dry Mode
Outdoor temperature
About 32 to 115 °F
Indoor temperature
About 64 to 90 °F
Outdoor
About 80% or less
temperature
68°F or obove
Indoor
Outdoor
About 50% or less
Humidity
temperature
below 68°F
ADDITIONAL CHARGE
Refrigerant suitable for a piping length of 25 ft (7.5 m) is charged in
the outdoor unit at the factory.
When the piping is longer than 25 ft (7.5 m), additional charging is necessary.
For the additional amount, see the table below.
Table 5
Pipe length
25 ft (7.5 m)
Additional
None
refrigerant
Between 25 ft (7.5 m) and 49 ft (15 m), when using a connection pipe
other than that in the table, charge additional refrigerant with 0.7 OZ/
3.3 ft (20g/1 m) as the criteria.
CAUTION
(1) When adding refrigerant, add the refrigerant from
the charging port at the completion of work.
(2) The maximum length of the piping is 15 m. If the
units are further apart than this, correct opera-
tion can not be guaranteed.
Large pipe
Outer diameter
Thickness
3/8"(9.52 mm)
1/32"(0.8 mm)
Heating Mode
About 17 to 75 °F
88 °F or less
33 ft (10 m)
49 ft (15 m)
1.8 oz (50 g)
5.3 oz (150 g)

STANDARD ACCESSORIES

The following installation accessories are supplied. Use them as re-
quired.
INDOOR UNIT ACCESSORIES
Name and Shape
Wall hook bracket
Remote
control unit
Battery (penlight)
Cloth tape
Remote control
unit holder
Tapping screw (big)
(ø4 × 20)
Tapping screw (small)
(ø3 × 12)
The following items are necessary to install this air conditioner. (The
items are not included with the air conditioner and must be purchased
separately.)
Name
Connection pipe assembly
Connection cord (3-conductor)
Wall pipe
Decorative tape
Vinyl tape
Wall cap
Saddle
Drain hose
Tapping screws
Sealant

ELECTRICAL REQUIREMENT

Always make the air conditioner power supply a special branch cir-
cuit and provide a special switch and receptacle. Do not extend the
power cord.
MINIMUM CIRCUIT AMPACITY
MAXIMUM OVERCURRENT PROTECTION
(TIME DELAY FUSE OR HACR TYPE CIRCUIT BREAKER)
Q'ty
Use
For indoor unit installation
1
Use for air conditioner
operation
1
For remote control unit
2
For indoor unit installation
1
Use as remote control unit
holder
1
For wall hook bracket
installation
8
For remote control unit
holder installation
2
CAUTION
9000 BTU/h 12000 BTU/h
12 A
15 A
15 A
20 A
Q'ty
1
1
1
1
1
1
1 set
1
1 set
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aou12r2Asu9r2Aou9r2

Table of Contents