Error Codes - GE GHDS830EDWS Technical Service Manual

Hide thumbs Also See for GHDS830EDWS:
Table of Contents

Advertisement

Error Codes

To check error codes:
1. Enter fi eld service mode.
2. Index to the Error Codes function (t6) by turning the knob. If there is more than one error, pressing the
START button will clear the displayed error code from the fault log and cause the next most recent error
to be displayed.
Control shall display error on SSD (7-segment display) model and LED model as per table.
ERROR CODE
"--" or "---"
No error
F01
Inlet thermistor short circuit. If temperature is greater than 120°F replace thermistor or
review connection; if temperature less than or equal to 120°F clear error.
F02
Outlet Thermistor short circuit. If temperature is greater than 120°F replace thermistor or
review connection; if temperature less than or equal to 120°F clear error.
F03
Inlet Thermistor Open circuit. If temperature is less than 40°F replace thermistor or review
connection; if temperature greater than or equal to 40°F clear error.
F04
Outlet Thermistor Open circuit. If temperature is less than 36°F replace thermistor or
review connection; if temperature greater than or equal to 36°F clear error.
F05
EEPROM Error. Replace the board.
F06
Stuck button. If a button is pressed longer that a minute this error is set; if no button stuck
clear error.
F07
*Miss-wire. Neutral wire improperly connected; Please ensure proper Neutral to center
terminal. If connection has been corrected; clear code as necessary.
F08
Door Switch Stuck Closed. Set when door has not opened for 5 cycles. This error is cleared
when door switch opens.
F09
Long dry times. Set when dryer reaches maximum cycle time. This error is cleared when
the dryer fi nishes cycle before reaching maximum time.
F010
Empty drum. Set when empty drum is detected; if no empty drum detected in a cycle this
error is cleared at the beginning of next cycle.
F011
Dry load. Set when dry load is detected; if cycle completes without dry load being detected
this error is cleared at the beginning of next cycle.
*When F7 appears on the control the user will be locked out from running the machine until the voltage is
the correct operating range. (See table below.)
Note: Dryer will operate normally with frequencies listed below automatically. Voltages are read from LINE
to NEUTRAL
DESCRIPTION
102V
5V - No F code
120V
5V - No F code
155V
5V - No F code
162V
Pulse - No F code
165V
0V - F07 Displayed
200V
0V - F07 Displayed
220V
0V - F07 Displayed
250V
0V - F07 Displayed
– 39 –

Hide quick links:

Advertisement

Table of Contents
loading