Test Frequency (MHz)
K,M
Channel
TX
1 : Center
160.100
2 : Low
146.100
3 : High
173.900
4
160.000
5
160.200
6
160.400
PCB Section
Item
Condition
1. Setting
1) Power supply voltage
DC Power supply terminal : 13.6V
2. VCO lock
1) CH : TX high
voltage*
2) CH : RX high
3) CH : TX low
4) CH : RX low
3. IF coil
1) CH : RX center (Wide)
2) SSG output : –53dBm (501µV)
Mod : 1kHz
Dev : 3kHz
4. RF
1) CH : RX center (Wide)
bandpass
CH : RX low (Wide)
filter
CH : RX high (Wide)
2) Tra generator output : –30dBm
Connect the spectrum analyzer
to BPF terminal
* Adjustment of TX VCO lock voltage
1. Remove R516, F501, R518 and R524 (all on component side).
2. Remove PCB from chassis.
3. Transmit and check voltage at [CV] point.
Warning : Do not transmit if step "1." is not complete.
4. Adjust of voltage can be done by tuning TC402.
ADJUSTMENT
K2,M2
RX
TX
160.050
149.100
149.050
146.050
136.100
136.050
173.950
161.900
161.950
160.000
149.000
149.000
160.200
149.200
149.200
160.400
149.400
149.400
Measurement
Test equipment
Digital voltmeter
SSG
Digital voltmeter
Tra generator
Spectrum analyzer
K,M
RX
Adjustment
Terminal
Parts
CV
TC402
5.5V
TC401
5.5V
Check
AFV
L301
3.25~3.35V (DC)
ANT
TC351
Adjust the BPF waveform
BPF
TC352
to Fig. 1
K2,M2
Fig. 1
TK-7102H
Specifications/
Method
Remarks
± 0.1V
± 0.1V
0.7V or more