3.2.2 Adjustment with Type 5824
Actuator
1. Retract the actuator stem by turning the
handwheel counterclockwise or by
applying a corresponding control signal
from the control device.
2. Continue as described in section 3.2.1.
Nominal size
K
0.4
VS
Set point range
flow rate m³/h
0.03...0.2 0.1...0.64 0.2...1.2 0.6...2.5 0.8...3.6
1)
Also available as version with flanged body
3)
A higher noise level will occur if the specified set point values are exceeded
Turns of the set point screw
12
8
11
7
10
9
6
8
7
5
7
6
6
4
5
5
4
3
4
3
3
2
2
1
0
0
0
0.01
0.02 0.03
Fig. 3 · Diagram for adjusting the flow rate
15
1
2.5
4
0.6...1.3
DN 15, K
0.4
0.05
0.1
0.2 0.3
3.2.3 Adjustment with Type 5825
Actuator
1. Switch the control device to manual mode
and change the control signal to retract
the actuator stem all the way and com-
press the spring mechanism.
20
25
6.3
8
3)
3)
0.8...2.3
0.8...3.5
0.8...5
DN20
...
vs
1
2.5
4
0.5
1
2
Operation
1)
32
40
2)
12.5
16/20
3)
3)
3)
2...5.8
3...9.1
4...14.1
2...10
3...12.5
2)
K
for flanged body
VS
25
32
40 50
3 4
5
10
15
EB 3135-1 EN
1)
50
2)
20/25
3)
4...15
V ˚
m 3 /h
7