Download Print this page

D: Audio Tests - Zydacron OnWAN Z340 Appendix

Test results

Advertisement

D:
AUDIO TESTS (ITU standards only)
As the second audio line input could not be activated on either unit, it was not
possible to carry out tests 2 or 3.
Test 1 was carried out with test signals inserted into the Headset Microphone input
with the Echo Canceller set to OFF. The audio output level was then adjusted by the
system volume control.
Test 1: Frequency response (-3dB)
(Insert a -30dB (Mic Level) signal at the local site, measure at remote site)
Test 2: Headroom (measured on G722 connection)
(Insert increasing amplitude 1 KHz tone at local site, monitor for overload
distortion at remote site)
Overload occurs at:
Test 3: Audio Level
(Insert -6dBm 1KHz tone at local site, monitor received level at remote site)
Remote site signal measures:
Test 4: Echo Cancellation
Setup
The echo canceller is fully automatic in operation.
Audio levels adequate? (Y/N)
Audio quality acceptable? (Y/N)
Echo cancellation acceptable? (Y/N)
Quality of double talk
Comments:
In tests with the JVCS Management Centre the received audio level
was measured as peaking between 0 and +4dBm. Tests were carried
out with AGC Off and the microphone level was adjusted to achieve
the correct received level at the management centre. With AGC On,
when the user was not speaking there was a high background noise
level. AGC status is selected from the Controls Menu.
*While the Echo Cancellation was acceptable there was a noticeable
residual echo at times.
10
G.722
G.728
5.6KHz
3.5KHz
Not Measured
Not Measured
Lecture Theatre
Not Tested
Not Tested
Not Tested
Not Tested
G.7111
3.3KHz
Room
Y
Y
Y*
Poor

Advertisement