Sanyo PLC-SL20 Service Manual page 13

Chassis no. ph3-sl2000, pg3-xl2000
Hide thumbs Also See for PLC-SL20:
Table of Contents

Advertisement

Electrical Adjustments
No.
Adjustment Item
30
ECO_TEMP_FAN1_MAX
31
ECOTEMP_FAN2_MIN
32
ECO_TEMP_FAN2_MAX
33
34
35
ECO_VALU_FAN1_MIN
36
ECO_VALU_FAN1_MAX
37
ECO_VALU_FAN2_MIN
38
ECO_VALU_FAN2_MAX
39
40
41
HINOR_TEMP_FAN1_MIN
42
HINOR_TEMP_FAN1_MAX
43
HINOR_TEMP_FAN2_MIN
44
HINOR_TEMP_FAN2_MAX
45
46
47
HINOR_VALU_FAN1_MIN
48
HINOR_VALU_FAN1_MAX
49
HINOR_VALU_FAN2_MIN
50
HINOR_VALU_FAN2_MAX
51
52
53
HIECO_TEMP_FAN1_MIN
54
HIECO_TEMP_FAN1_MAX
55
HIECOTEMP_FAN2_MIN
56
HIECO_TEMP_FAN2_MAX
57
58
59
HIECO_VALU_FAN1_MIN
60
HIECO_VALU_FAN1_MAX
61
HIECO_VALU_FAN2_MIN
62
HIECO_VALU_FAN2_MAX
63
64
65
CLNOR_TEMP_FAN1_MIN
66
ClNOR_TEMP_FAN1_MAX
67
CLNOR_TEMP_FAN2_MIN
68
CLNOR_TEMP_FAN2_MAX
69
70
71
CLNOR_VALU_FAN1_MIN
72
CLNOR_VALU_FAN1_MAX
73
CLNOR_VALU_FAN2_MIN
74
CLNOR_VALU_FAN2_MAX
75
76
77
CLECO_TEMP_FAN1_MIN
78
CLECO_TEMP_FAN1_MAX
79
CLECOTEMP_FAN2_MIN
80
CLECO_TEMP_FAN2_MAX
81
82
83
CLECO_VALU_FAN1_MIN
84
CLECO_VALU_FAN1_MAX
85
CLECO_VALU_FAN2_MIN
86
CLECO_VALU_FAN2_MAX
87
88
89
FAN1_ADJUST_VOLT_MIN
90
FAN1_ADJUST_VOLT_MAX
91
FAN2_ADJUST_VOLT_MIN
92
FAN2_ADJUST_VOLT_MAX
93
94
Group: 112 PC Real/ AV Cinema
0
PC Real Contrast
1
PC Real Brightness
2
PC Real Red
3
PC Real Green
4
PC Real Blue
5
PC Real Gamma
6
AV Cinema Contrast
7
AV Cinema Brightness
8
AV Cinema Color
9
AV Cinema Tint
10
AV Cinema Red
11
AV Cinema Green
12
AV Cinema Blue
13
AV Cinema Sharpness
14
AV Cinema Gamma
15
AV Cinema N.R.
16
AV Cinema PROGRESSIVE
Initial Value
Range
Input source / Description
48/84
Control End Temperature for for FAN1 at Eco Mode
41/47
0~255
Control Start Temperature for FAN2 at Eco Mode
48/54
Control End Temperature for for FAN2 at Eco Mode
70/70
Minimum Control Value for FAN1 at Eco Mode
135/135
Maximum Control Value for FAN1 at Eco Mode
85/85
0~255
Minimum Control Value for FAN2 at Eco Mode
130/130
Maximum Control Value for FAN2 at Eco Mode
41/48
Control Start Temperature for FAN1 at Highland Normal Mode
48/54
Control End Temperature for FAN1 at Highland Normal Mode
41/48
0~255
Control Start Temperature for FAN2 at Highland Normal Mode
48/54
Control End Temperature for FAN2 at Highland Normal Mode
80/80
Minimum Control Value for FAN1 at Highland Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
135/135
Maximum Control Value for FAN1 at Highland Normal Mode
95/100
0~255
Minimum Control Value for FAN2 at Highland Normal Mode
135/135
Maximum Control Value for FAN2 at Highland Normal Mode
41/47
Control Start Temperature for FAN1 at Highland Eco Mode
48/54
Control End Temperature for FAN1 at Highland Eco Mode
41/47
0~255
Control Start Temperature for FAN2 at Highland Eco Mode
48/54
Control End Temperature for FAN2 at Highland Eco Mode
70/70
Minimum Control Value for FAN1 at Highland Eco Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
135/135
Maximum Control Value for FAN1 at Highland Eco Mode
85/85
0~255
Minimum Control Value for FAN2 at Highland Eco Mode
130/130
Maximum Control Value for FAN2 at Highland Eco Mode
41/48
Control Start Temperature for FAN1 at Ceiling Normal Mode
48/54
Control End Temperature for FAN1 at Ceiling Normal Mode
41/48
0~255
Control Start Temperature for FAN2 at Ceiling Normal Mode
48/41
Control End Temperature for FAN2 at Ceiling Normal Mode
80/80
Minimum Control Value for FAN1 at Ceiling Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
135/135
Maximum Control Value for FAN1 at Ceiling Normal Mode
95/100
0~255
Minimum Control Value for FAN2 at Ceiling Normal Mode
135/135
Maximum Control Value for FAN2 at Ceiling Normal Mode
41/47
Control Start Temperature for FAN1 at Ceiling Eco Mode
48/54
Control End Temperature for FAN1 at Ceiling Eco Mode
41/47
0~255
Control Start Temperature for FAN2 at Ceiling Eco Mode
48/54
Control End Temperature for FAN2 at Ceiling Eco Mode
70/70
Minimum Control Value for FAN1 at Ceiling Eco Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
135/135
Maximum Control Value for FAN1 at Ceiling Eco Mode
85/85
0~255
Minimum Control Value for FAN2 at Ceiling Eco Mode
130/130
Maximum Control Value for FAN2 at Ceiling Eco Mode
1
DAC Adjustment Value at minimum driving voltage for FAN1
230
DAC Adjustment Value at maximum driving voltage for FAN1
1
0~255
DAC Adjustment Value at minimum driving voltage for FAN2
230
DAC Adjustment Value at maximum driving voltage for FAN2
32
0 ~ 63
32
0 ~ 63
34
0 ~ 63
32
0 ~ 63
31
0 ~ 63
8
0 ~ 15
32
0 ~ 63
32
0 ~ 63
32
0 ~ 63
32
0 ~ 63
32
0 ~ 63
30
0 ~ 63
29
0 ~ 63
8
0 ~ 31
8
0 ~ 15
1
0 ~ 2
1
0 or 1
-13-
SVGA/XGA
SVGA/XGA
SVGA/XGA
✻ Fan Control Adjustment
✻ Fan Control Adjustment
✻ Fan Control Adjustment
✻ Fan Control Adjustment

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xl20Plc-su50

Table of Contents