4. Water Controllers

All water controllers must be installed in accordance with the relevant operation/installation instructions
supplied with the water heater or controllers.
Care should be taken to ensure power supply to the Infinity is isolated when
connecting / disconnecting controller wiring or transponder on wireless controllers.
NOTE
Failure to isolate power supply may result in damage to the appliance PCB.
Care should be taken when closing the Ezi-connect access panel, to ensure internal
wiring for controllers is not shortened or crushed.
Trouble shooting
Water Controller not showing display - (Wired Water Controllers)
Check that the correct number and combination of controllers have been installed for the specific
model Infinity. Refer to controller compatibility table below.
Check controller is turned ON.
Check there is 12VDC power supply available to the controller from the Ezi-connect terminals.
If there is 12VDC available from the Ezi Connect but no controller display, check wiring between
Ezi-connect and controller is sound.
If there is no power from the Ezi-connect terminals, but the hot water functions correctly, replace
PCB.
Error Code 12 as soon as hot water tap is turned ON.
Check 12VDC internal wiring to Ezi-connect terminal is not crushed, or shortened.
Rectify wiring and re-close Ezi-connect cover carefully.
Water Controller not showing display - (Wireless Water Controllers)
Ensure transceiver module is mounted in the correct location, as per wireless controller installation
instructions.
Ensure 2 x AA batteries are in good working order and installed with the correct polarity within the
wireless controller. (Battery polarity details on rear of wireless controller)
Ensure distance between wireless controller and transceiver does not exceed 50 metres.
Ensure channel has been allocated to each wireless controller.
Ensure wireless controller has been programmed to the transceiver correctly, as per wireless
controller installation instructions.
Water Controller Compatibility Table
A maximum of 4 wireless water controllers can be fitted with the following limitation:
Wireless Only
Only ONE MC-502RC or MC-503RC can be set as the Master Controller.
Installation
A maximum of 4 water controllers can be fitted. Any combination of deluxe, universal and
wireless controllers can be used with the following limitation:
Only ONE master controller can be installed. This can be a MC-100V, a MC-91Q (when
Wired &
programmed as a master controller) or a MC-502RC or MC-503RC water controller.
Wireless
Installations
Up to TWO BC-100V water controllers can be installed.
The FOURTH water controllers in any installation MUST BE a MC-502RC/MC-503RC
or a MC91Q.
REU-VR1620WG / REU-VR1620WB / REU-VR1620WS / REU-VR2024WG- 6 -