6.2.2 Roof anchor type S and roof anchor type S
flat (for beaver tail)
a
Caution!
The roof may collapse!
Before installation on the roof batten, check
the load capacity of the roof batten!
Replace the roof batten if necessary.
2
Fig. 6.6 Fixing the roof anchor type S
1. Uncover the rafters or the roof batten where needed.
For distances please see Tab. 6.2 and 6.3.
2. Position the roof anchor. Pay attention to the correct
position of the upper and lower roof anchor (see Fig.
6.3).
3. Screw the roof anchor to the rafters/roof batten with
the 3 supplied bolts.
4. Slide the pantiles back to the original position.
Installation manual auroTHERM 0020057143_04
3
1
On-roof mounting 6
4
GB