8 Self-check Function

Use the self-check function to test the unit.
1. Checking the IIC bus lines
2. Power LED Blinking timing
8.1.
Check of the IIC bus lines
8.1.1.
How to access
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control
for more than 3 seconds.
8.1.2.
Exit
Disconnect the AC cord from wall outlet.
8.1.3.
Screen display