Support Matrix For Cisco Ucs C240 M4 Server Raid Controllers; Cisco Ucs Sas 9300-8E Hba Considerations; Mixing Rules; Cisco Ucs 9300-8E Bad Drive And Predictive Failure Behavior - Cisco c240 Installation And Service Manual

Ucs c240 m4 server
Table of Contents

Advertisement

Support Matrix For Cisco UCS C240 M4 Server RAID Controllers

Support Matrix For Cisco UCS C240 M4 Server RAID Controllers

Table C-2
Table C-2
Support Matrix For C240 M4 RAID Controllers
Boot SSD
C240 M4
(Internal)
Version
Supported?
SFF 8 HDD
No
LFF 12 HDD Yes
SFF 16 HDD No
SFF 24 HDD Yes

Cisco UCS SAS 9300-8e HBA Considerations

This section contains the following topics:

Mixing Rules

Do not mix the Cisco UCS 9300-8e HBA in the same server as the Cisco UCS 12G SAS Modular HBA.

Cisco UCS 9300-8e Bad Drive and Predictive Failure Behavior

The bad drive and predictive failure behavior for the Cisco UCS SAS 9300-e HBA cards is different than
that for LSI MegaRAID cards. The list below compares behavior for these HBA cards and LSI
MegaRAID cards.
Cisco UCS C240 M4 Server Installation and Service Guide
C-4
lists the support for the available controllers by server version.
Embedded
Software
AHCI
RAID
Mode
Control
Control
Boot SSD
Boot SSD
(Internal)?
(Internal)?
N/A
N/A
Yes
Yes
N/A
N/A
Yes
Yes
Mixing Rules, page C-4
Cisco UCS 9300-8e Bad Drive and Predictive Failure Behavior, page C-4
Setting the Preferred Boot Device for Cisco UCS 9300-8e, page C-5
Bad/invalid/0MB drive handling:
MegaRAID: The bad drive is marked BAD in the GUI/CLI interfaces and the fault LED on the
drive is solid amber.
HBA: The bad drive is not shown in the GUI/CLI and there is no LED indication.
Drive predictive failure:
MegaRAID: If the drive is part of a RAID volume with a spare, the software performs an
auto-copy backup and then marks the drive failed/BAD with the fault LED on the drive solid
amber.
HBA: There is no error handling and there is no LED indication. The operating system must
handle the fault.
Hardware
Embedded
Controller
Software
Card
RAID
Control
Control
Boot SSD
Front-Facing
(Internal)?
drives?
N/A
Yes
No
No
N/A
No
No
No
Appendix C
RAID Controller Considerations
Cisco 12G
Modular
RAID
AHCI mode
Controller
Control
Card Control
Front-Facing
Front-Facing
drives?
Drives?
No
Yes
No
Yes
No
Yes
No
Yes
SAS 9300-8i
HBA Controller
Card Control
Front-Facing
Drives?
N/A
Yes
N/A
Yes
OL-32474-01