7. To change velocity unit, press"POWER/HOLD"and
"UNIT/MODE"simultaneously while in velocity mode.
8. To change temperature unit,press"POWER/HOLD"
and "UNIT/MODE" simultaneously while in any
temperature mode.
9. Turn off the meter by pressing "POWER/HOLD"
button more than 3 seconds.
10. Unplug the probe and put back the anemometer
into soft pouch to protect the vane impeller.

Auto Power Off

This instrument will shut off automatically in approx. 5
minutes of inactivity. For operating over longer period of
time, disable the sleep mode by pressing
"POWER/HOLD" more than 3 seconds before power
on until a "n" appears in the middle of the screen
(Fig.3) and then release key to return to the normal
measurement mode.
SPECIFICATIONS
Velocity Range : 0.5~44.7M/H, 60~3937FT/M,
Resolution :0.1M/H,2FT/M,0.1KNT,0.1M/S,0.1KMH,1BF
Accuracy : +/-5% of reading or +/-last significant digit
Air Temp. Range :0~50°C (32°F~122°F)
Resolution : 0.1°C
Accuracy : +/-1°C
Humidity Range : 5~95%RH
Resolution :0.1%RH
0.4~38.8KNT, 1.1~20.0M/S,
0.8~72.0KMH, 1~8BF
(whichever is greater)