Cracking­or­­
discolouration­of­
pump/bottle­parts
Pump­not­­
responding
Pump­light­­
flashing­RED
Difficulties­separating­
the­control­handle­
from­the­pump­body
19
•­ Avoid­contact­with­antibacterial­or­abrasive­­
detergents/cleaners­as­they­can­damage­the­­
plastic.­Combinations­of­detergents,­cleaning­
products,­sterilising­solution,­softened­water­­
and­temperature­fluctuations­may,­under­certain­­
circumstances,­cause­the­plastic­to­crack.­If­this­
occurs,­do­not­use.­The­pump­body­and­breast­­
milk­containers­are­dishwasher­safe­but­food­
colourings­may­discolour­them.­Follow­guidelines­
in­'How to clean and sterilise your pump'.
•­ Keep­the­product­out­of­direct­sunlight,­as­
prolonged­exposure­may­cause­discolouration.
•­ Ensure­the­pump­is­correctly­assembled­and­switched­
on­with­the­power­indicator­illuminated­'GREEN'.
•­ Make­sure­the­lead­between­the­electrical­wall­socket­
or­battery­pack­and­the­pump­is­correctly­connected.
•­ Pump­light­flashing­RED­with­delays­(3­flashes,­delay,­
3­flashes­etc.):­If­the­pump­works­properly­in­Manual­
Control­Mode­but­does­not­replicate­in­Automatic­
Mode,­the­handle­rhythm­may­have­been­too­fast­for­
optimal­milk­expression.­The­machine­is­set­not­to­
follow.­Push­the­control­button­to­return­to­Manual­
Control­Mode­and­use­a­slower­handle­rhythm.
•­ If­this­does­not­help­and­the­power­light­still­
flashes­RED,­the­pump­has­detected­a­vacuum­fault.­
Disconnect­the­power­and­check­the­control­­
handle­and­diaphragm­for­obstruction­or­damage.
•­ Pump­light­flashing­RED­continuously:­Low­battery­
warning.­Replace­the­batteries.
•­ The­pump­must­be­switched­off­via­the­control­
button­in­order­to­separate­these­parts.­If­the­­
batteries­go­flat­mid-pumping,­you­may­­
experience­difficulty.­Replace­the­batteries­or­­
connect­the­pump­to­the­mains.­Turn­the­pump­
on­by­holding­down­the­control­button­for­2­­
seconds­–­the­light­will­turn­GREEN.­Now­turn­it­
off­by­holding­the­button­for­2­seconds­–­the­light­
will­go­off.­You­can­now­disconnect­the­pump­
from­the­power­supply­and­should­be­able­to­­
separate­the­parts.