HEATER / FAN / LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control de-
vice.
8. Never place a switch where it can be reached from a tub or
shower.
9. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer.
10. This unit must be grounded.
CAUTION
1. Provide a separate 20 AMP circuit. Use 12 GA. power cable
of type which meets code. Use supply wiring rated for at least
O
90
C.
2. This product is designed for ceiling installation only. This prod-
uct is designed for installation in ceilings up to a 12/12 pitch.
Ductwork must point up. DO NOT MOUNT THIS PRODUCT
IN A WALL.
3. Install in ceiling only, at least 12" from any wall.
4. For greatest efficiency, install heater so heat is directed toward
tub or shower area. Avoid directing toward walls or windows.
5. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
6. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc., off pow-
er unit.
7. Please read specification label on product for further informa-
tion and requirements.
To register this product, visit:
www.nutone.com
USE AND CARE
DISCONNECT ELECTRIC POWER SUPPLY BEFORE CLEAN-
ING OR SERVICING THIS UNIT.
TO REPLACE BULB:
Remove lens by gently depressing sides and pull down. Use
bulb rated up to 100 watts only.
TO CLEAN LENS AND GRILLE:
Remove lens as explained above. Remove bulb. Remove acorn
nut in center of light reflector and lower assembly. Unplug light.
CAUTION: Grille and reflector are separate units.
Plastic parts can be cleaned with mild, soapy water and dried
with a soft cloth. DO NOT USE ABRASIVE CLOTHS, STEEL
WOOL PADS, OR SCOURING POWDERS.
TO CLEAN FAN ASSEMBLY:
Unplug fan motor. Remove retaining screws.
CAUTION: Fan assembly will swing downward when screws are
removed. Support the fan assembly with a free hand while re-
moving retaining screws.
Gently vacuum fan, motor and interior of housing. Motor is per-
manently lubricated and never needs oiling.
TO CLEAN HEATER ASSEMBLY:
Unplug heater. Remove retaining screw. Place a screwdriver
tip between outer wall of housing and heater exhaust opening.
Gently pry outward until exhaust housing slips out.
CAUTION: Unit will swing downward when released. Support
with the heater assembly with a free hand while prying with
screwdriver.
Gently vacuum blower, motor and interior of housing. Motor is
permanently lubricated - never needs oiling.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IM-
MERSED IN WATER.
TO REASSEMBLE ALL ABOVE PARTS:
Reverse all procedures explained above. Assemblies should not
be disassembled any further than explained above.
MODEL 665RP
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for NuTone 665RP

  • Page 1 MODEL 665RP Page 1 HEATER / FAN / LIGHT To register this product, visit: www.nutone.com READ AND SAVE THESE INSTRUCTIONS WARNING USE AND CARE TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- DISCONNECT ELECTRIC POWER SUPPLY BEFORE CLEAN- JURY TO PERSONS, OBSERVE THE FOLLOWING: ING OR SERVICING THIS UNIT.
  • Page 2: Prepare The Unit

    MODEL 665RP Page 2 PREPARE THE UNIT INSTALL THE UNIT 1. Remove the lamp For best results, choose a location which allows fan holder assembly. to be vented outside with the shortest possible duct run and the fewest num- ber of elbows.
  • Page 3 MODEL 665RP Page 3 4. Use a flat-bladed screwdriver to remove the proper electrical knockouts. WIRE OPENING RELEASE SLOT If the switch has not been wired properly and wires need to be moved: 1. Each wire opening has a release slot.
  • Page 4: Service Parts

    BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 5: Uso Y Cuidado

    MODELO 665RP Página 5 CALENTADOR / VENTILADOR / LÁMPARA Para colocar este producto, visite: www.nutone.com LEA Y CONSERVE ESTAS INSTRUCCIONES 5. Sólo para usarse como medio de ventilación general. No debe ADVERTENCIA usarse para descargar materiales ni vapores peligrosos o explosivos.
  • Page 6: Preparación De La Unidad

    MODELO 665RP Página 6 PREPARACIÓN DE LA UNIDAD INSTALACIÓN DE LA UNIDAD Para obtener los mejores 1. Saque el conjunto resultados, elija un sitio del portalámpara. que permita descargar el ventilador hacia el aire libre y donde se requiera el tramo de conductos más corto posible...
  • Page 7 MODELO 665RP Página 7 4. Con un destornillador plano, saque las tapas removibles RANURA DE apropiadas. ENTRADA PARA CABLE DESENGANCHE Si el interruptor no está conectado apropiadamente y hay que cambiar los cables: 1. Cada entrada para cable tiene una ranura de desenganche.
  • Page 8: Piezas De Repuesto

    INCLUYENDO, PERO NO LIMITADAS A, GRANTÍAS NO EXPRESADAS DE MERCHNTIBILIDAD O ADAPTABLES A UN PROPÓSITO EN PARTICULAR. Durante este período de un año, Broan-NuTone reparará o reemplazará a su opción y sin costo, cualquier producto o parte que se encuentre defectuoso bajo condiciones normales de uso y servicio.

This manual is also suitable for:

65rp

Table of Contents