Brother FAX-170 Service Manual page 100

Hide thumbs Also See for FAX-170:
Table of Contents

Advertisement

Selector
No.
CNG detection when sharing a
1
modular wall socket with a telephone
2
Min. detection time length of
|
PABX* dial tone, required for
starting dialing
4
CNG detection when sharing a
5
modular wall socket with a telephone
6
Dial tone detection in PABX*
7
8
"R" key function
NOTE: Selectors 2 through 4 and 6 through 8 are not applicable where no PABX is installed.
Selectors 1 and 5: CNG detection when sharing a modular wall socket with a telephone
These selectors determine whether or not the equipment detects a CNG signal when a line
is connected to a telephone sharing a modular wall socket with the equipment. If these se-
lectors are set to "0,0," the equipment does not detect CNG. If set to other selector values,
the equipment interprets CNG as an effective signal upon detection of CNG signals by the
number of cycles specified by these selectors and then starts FAX reception.
Selector
No.1
No. 5
0 (A)
0 (A)
0 (A)
1 (B)
1 (B)
0 (A)
1 (B)
1 (B)
Selectors 2 through 4:
Upon detection of the PABX dial tone for the time length set by these selectors, the equip-
ment starts dialing.
These selectors are effective only when both selectors 6 and 7 are set to "1" (Detection).
WSW03
(PABX* mode setting)
Function
Cycle
No detection
One cycle
1.5 cycles
2 cycles
Min. detection time length of PABX dial tone, required for starting
dialing
V – 12
Setting and Specifications
0: A
1: B
No. 2
3
4
0
0
0
:
0
0
1
:
210 ms
0
1
0
:
500 ms
0
1
1
:
800 ms
1
0
0
:
900 ms
1
0
1
:
1.5 sec.
1
1
0
:
2.0 sec.
1
1
1
:
2.5 sec.
0: A
1: B
No. 6
7
0
0
:
No detection
(3.5 sec. WAIT)
0
1
:
No detection
(5 sec. WAIT)
1
0
:
No detection
(7 sec. WAIT)
1
1
:
Detection
(Frequency only)
0: 1st dial tone
1: No 1st dial
detection add
* PABX: Private automatic branch exchange
50 ms
tone detection