8. COMPRESSOR CONTROL

1. OPEARTION FREQUENCY RANGE
The operation frequency of the compressor is different based on the operation mode as
shown in the Table 10.
(Table 10 : Compressor Operation Frequency Range)
AOU9RLFW1
AOU12RLFW1
2. OPEARTION FREQUENCY CONTROL AT START UP
The compressor frequency soon after the start-up is controlled as shown in the Fig. 9.
(Fig. 9 : Compressor Control at Start-up)
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
(Frequency)
AOU9RLFW1
AOU12RLFW1
(Time)
AOU9RLFW1
AOU12RLFW1
3. LIMITATION OF COMPRESSOR FREQUENCY BY OUTDOOR TEMPERATURE
The minimum compressor frequency is limited by outdoor temperature as shown in the Table 11.
(Table 11 : Limitation of Compressor Frequency)
[ Cooling/ Dry ]
AOU9RLFW1
AOU12RLFW1
[ Heating ]
AOU9RLFW1
AOU12RLFW1
Cooling
Min
Max
22rps
79rps
18rps
96rps
Time
Time
Frequency
Frequency
70rps
82rps
56rps
74rps
Time
Time
80sec
140sec
80sec
140sec
50°F(10°C)
57.2°F(14°C)
Under
Over
Under
34rps
28rps
39rps
27rps
26.6°F(- 3°C)
44.6°F(7°C)
Under
Over
Under
42rps
39rps
36rps
27rps
Heating
Min
Max
22rps
99rps
18rps
130rps
Time
Time
Frequency
Frequency
92rps
96rps
87rps
97rps
Time
Time
200sec
380sec
200sec
380sec
104°F(40°C)
Over
Under
Over
22rps
30rps
30rps
18rps
57.2°F(14°C)
Over
Under
Over
28rps
23rps
27rps
18rps
01-08
Dry
Min
Max
28rps
37rps
25rps
33rps
Time
Time
Frequency
Frequency
96rps
108rps
Time
Time
440sec
440sec
104°F(40°C)
Under
Over
30rps
30rps
96rps
119rps
440sec
500sec