Memory Stick Problems Back Side L - Z Audio Internal Problems This document is Sony Ericsson confi dential and should be treated as confi dential in accordance Audio External Problems FUNCTIONAL OVERVIEW with the agreement with Sony Ericsson. This document is intended for use by authorized service...
Note: More additional information about the equipment used for TRS can be found in Repair Tools Catalogue on CSPN or on the following location: CSPN – Repair Instructions – Electrical – K850 – Equipment List. Spectrum Analyzer HP 8595E or similar...
Page 4
SEMC Troubleshooting Manual TROUBLESHOOTING Equipment List K850 Urquell Fault Trace SW with project file RF Test Cable Flexible Location: CSPN-Repair Instructions-Electrical-Trouble Shooting Application Location: CSPN-Repair Instructions-Level: Mechanical-Tool Catalogue Project File: K850Project_R1A Part number: RPM 119 885 Se Picture 4. Drivers...
Page 5
SEMC Troubleshooting Manual TROUBLESHOOTING Equipment List K850 STEP 1: STEP 4: Take the CST-75 battery charger and cut of the charger according to Picture 6. Connect DCIO and SEPI Interface Cable – A1 cables according to Picture 9. Picture 6 Picture 9 Note: Cable length must be exact 1.3m.
Page 6
SEMC Troubleshooting Manual TROUBLESHOOTING Equipment List K850 STEP 2: Correct DCIO/SEPI Cable setup without the TRS Fixture. Cut the Red lab plug according to Picture 15 Picture 12 Picture 15 STEP 3: Picture 13 Use any Hands free (PHF) Cable and cut according to Picture 16 Picture 16 Note: Minimum Cable length 40 cm.
Page 7
SEMC Troubleshooting Manual TROUBLESHOOTING Equipment List K850 STEP 5: Test SIM GSM/UMTS Connect by soldering cable from Picture 15 and cable from Picture 17 according to Picture 18. One Test SIM GSM/UMTS is needed to perform Current Consumption Test, se Picture 21.
SEMC Troubleshooting Manual TROUBLESHOOTING On/Off Problems / Flash Problems K850 On/Off problems Flash problems START Step 1: Perform System START Connector Protection Test. Is the phone Go to Flash process Step 2: consuming more than Start-up Phone with Normal SW...
SEMC Troubleshooting Manual TROUBLESHOOTING Dead Phone Problems K850 Dead Phone problems part 1 Dead Phone problems part 2 START SL 4 Replace S2400 Dead Phone VBT27 Keep S2400 Step 1: Replace N1400, C1409 N1400 not pressed problems Voltage pressed or...
SEMC Troubleshooting Manual TROUBLESHOOTING Display Problems / Display Illumination Problems K850 Display problems Display illumination problems START Step 1: Use TRS Fixture and connect the display and the keypad. Connect VBATT. Use Fault Trace SW If the display is working properly at the...
SEMC Troubleshooting Manual TROUBLESHOOTING Key Problems / LED Problems K850 Key problems LED problems On Red LED START START problems: Replace Replace Step 1: SL 5 Replace More than Use Fault Trace SW Load ITP SW into the phone. V2402...
SEMC Troubleshooting Manual TROUBLESHOOTING Main Camera Problems / VGA Camera Problems K850 START Main Camera problems VGA Camera problems Load ITP SW into the phone. Use TRS Fixture and Fault Trace SW Connect: Display and Main Camera Module Connect: VBATT and DCIO/SEPI...
SEMC Troubleshooting Manual TROUBLESHOOTING Camera Door Problems / Vibrator Problems K850 Camera Door problems Vibrator problems START START Load ITP SW into the phone Use TRS Fixture. Load ITP SW Fault trace SW Connect: VBATT and DCIO/SEPI into the phone.
SEMC Troubleshooting Manual TROUBLESHOOTING FM Radio Problems / Bluetooth Problems K850 FM Radio problems Bluetooth problems Replace START Load ITP SW START N1400 Into the phone Go to Flash the phone with the Speaker and Use TRS Fixture Change the...
SEMC Troubleshooting Manual TROUBLESHOOTING Xenon Flash Problems K850 Xenon Flash problems START Disassemble the Fault trace SW Load ITP SW phone Xenon Flash Test into the phone. Use TRS Fixture Led and Backlight Insert Dummy Battery Connect Display and Activate:...
SEMC Troubleshooting Manual TROUBLESHOOTING System Connector Protection Test / Current Comsumption Test K850 System Connector Protection Test Current Consumption Test Step 1: Perform Diode and Ohm measurements with DMM Connect the black probe at ground (Pin 9 system connector) Insert Local SIM Card and use the phone with the Normal SW (SSW) and dummy battery connected to Power Supply Channel 1 VBATT according to Picture 1.
Page 21
SEMC Troubleshooting Manual TROUBLESHOOTING Current Comsumption Test K850 Transmitter current 850 MHz at Ch: 128 power level 5. Typical 400mA Max TX Power GSM 1800 MHz Transmitter current 900 MHz at Ch: 1 power level 5. Typical 400mA Transmitter current 1800 MHz at Ch: 512 power level 0. Typical 400mA Fault Trace SW settings: Transmitter current 1900 MHz at Ch: 512 power level 0.
Limiter: 2A. This test should be preformed in 3 steps: If test is performed at the Core Level then use dummy battery according to the K850 Step1: Equipment List for this test. If using TRS Fixture no dummy battery is needed.
SEMC Troubleshooting Manual TROUBLESHOOTING Test Charging / ASIC Revision Test K850 ASIC Revision Test Test Charging To perform this test use: Purpose with this test is to check following items: Phone with the Normal SW (SSW) Dummy Battery connected to Power Supply Channel 1 VBATT...
SEMC Troubleshooting Manual MEASUREMENT POINTS Power Top K850 VCORE18 VBATI Power Memories Power Memories VBATI CAM_LDO_EN VBATI CAM_LDO_EN CAM_LDO_EN VCAMAF VCAMAF VCAMAF VCAMSA VCAMSA VCAMSA VCAMIO VCAMIO VCAMIO VCAML VCAML VCAML VCAMSD VCAMSD VCAMSD Power Camera Power Camera VDDE18 VDDE18...
The analog baseband controller is controlled by an I2C™ interface. It also comprises the main power management circuits, equipped with a number of converters and regulators for Hardware Overview generating the required supply voltages. The K850 is using the U360 platform provided by Ericsson Mobile Platform (EMP) 1203-2528 rev. 1 (101)
Page 63
SEMC Troubleshooting Manual FUNCTIONAL OVERVIEW Technical Description K850 Functional Blocks of the Analog Baseband Controller. Connection Diagram 1203-2528 rev. 1 (101)
Page 64
SEMC Troubleshooting Manual FUNCTIONAL OVERVIEW Technical Description K850 Charger Control Resistance Identification and Temperature Measurement The resistance identification mode utilizes the constant current source to feed the battery data A programmable charger is used for battery charging. output while monitoring the voltage at the battery data node with general purpose ADC. The Limits can be set for the output voltage at CHSENSE- and the output current from DCIO conversion is started through I2C.
Page 65
SEMC Troubleshooting Manual FUNCTIONAL OVERVIEW Technical Description K850 CODEC Block Schematic CODEC CCO Voltage Source There is an internal voltage source CCO that provides the necessary drive current for electret microphones. The voltage source is I²C programmable to 2.2 V or 2.4 V. The source can be disabled during standby.
Page 66
SEMC Troubleshooting Manual FUNCTIONAL OVERVIEW Technical Description K850 Digital Baseband Controller (CPU) Functional blocks of the Digital Baseband Controller D2000 (Anja) This component is not replaceable on SL 4 because Baseband calibration is required. The Digital Baseband Controller is divided in two subsystems:...
Page 67
SEMC Troubleshooting Manual FUNCTIONAL OVERVIEW Technical Description K850 Radio Modules RF System Control The access subsystem of the digital baseband controller controls the overall radio system. In GSM/GPRS/EDGE Radio Module both EDGE/GSM/GPRS and WCDMA air interface mode, the digital baseband controller controls N1200 (Thor) the radio system through a 3-wire serial bus.
Page 68
SEMC Troubleshooting Manual FUNCTIONAL OVERVIEW Technical Description K850 Block diagram of the GSM/EDGE Transceiver TX Frequency, Channel and Power Level Range: GSM 850: Frequency Range: 824,2 MHZ – 848,8 MHZ Channel Range: 128 – 251 Power Level: Min: 19 – Max 5 GSM 900: Frequency Range: 890,2 MHZ –...
Page 69
SEMC Troubleshooting Manual FUNCTIONAL OVERVIEW Technical Description K850 WCDMA Radio Module WCDMA Transceiver Block Diagram N1210 (Mammoth) In WCDMA the differential transmit outputs from the WCDMA transceiver are filtered by an external SAW filter. The SAW filter cleans up the spectrum and also provides a single ended drive signal to the power amplifier.
Page 70
SEMC Troubleshooting Manual FUNCTIONAL OVERVIEW Technical Description K850 The front-end zero IF I and Q outputs are applied to the integrated low-pass channel filter. The filter is self-calibrated with a cut-off frequency around 2.15 MHz. The filter may be configured in...
SEMC Troubleshooting Manual FUNCTIONAL OVERVIEW Power Distribution & Clocking Concept K850 Power Distribution Clocking Concept 32 kHz SYSCLKREQ WCDMA GSM PA DC/DC Flash WCDMA PA xxRAM xxRAM NAND card AB 3100 WCDMA PA SERCON UART WCDMA PA EMIF EMIF NAND...
SEMC Troubleshooting Manual APPENDIX Replaceable Parts K850 Part List Main Board Contains only components that are possible to replace on the main board. Pos. number refers to the components position number on the board. Some components are noted as MSL X. These components are moisture-sensitive and are rated at...
SEMC Troubleshooting Manual APPENDIX Components N2205 - N2208 K850 N2205 IC Voltage Regulator 1200-0107 N2208 IC Voltage Regulator RYT113997/4 Connection Diagrams Pin Descriptions Power Supply Voltage Input to the internal PFET switch. Analog Supply Input. Enable Input. Set this digital input high for normal operation. For shutdown, set this pin low.
ITP SW. Using this software you can control most parts and functions of all Sony Ericsson mobile phones. It is a Note: There are some differences in the user interface depending on the phone project file loaded.
Page 94
SEMC Troubleshooting Manual APPENDIX Troubleshooting Software Documentation K850 Equipment Setup Power Supply Channel 2 DCIO/SEPI Cable Connection Setup Note: The Power Supply Channel 1 (VBATT) must allow reverse current. Note: During calibration the accurate voltage from VBATT must be within ±0.015 V. If this is not Note: The maximal cable length between the Power Supply Channel 1 VBATT and the dummy battery fulfilled it will cause a faulty calibration.
Page 95
SEMC Troubleshooting Manual APPENDIX Troubleshooting Software Documentation K850 GSM Radio Settings System Requirements Note: Before start using the Troubleshooting Software, the phone must be flashed with ITP SW. Used for Channel and Power Level control of the selected GSM Band. The TX and RX frequency value for selected band and channel will be presented in the TX and RX frequency box.
Page 96
SEMC Troubleshooting Manual APPENDIX Troubleshooting Software Documentation K850 Fast select channels VCXO Control Set High Channel: The High Channel for selected WCDMA Band will be set by the Troubleshooting SW. Used to fine tune the VCXO to MCLK frequency by calibrating the DAC that sets the VCXO control voltage.
Page 97
OFF is used to switch off the currently used Audio Loop. Examples of different Audio Loop Test setups in Fault Trace SW. Picture 9 Picture 10 K850 Project FM Radio Setup K800 Project FM Radio Setup Logic – Tab K800 Project Setup...
Page 98
SEMC Troubleshooting Manual APPENDIX Troubleshooting Software Documentation K850 Current Calibration Memory stick test checks the communication with the Memory stick card. The test result (Passed or Failed) will be displayed in the info box. The Current Calibration test is similar to the Current Test for the charging algorithm in the factory Note: A Memory stick card must be inserted and a Memory card reader connected to run this test.
Page 99
SEMC Troubleshooting Manual APPENDIX Troubleshooting Software Documentation K850 Camera Door Test Fault Trace SW Error Messages Vibrator Test Keyboard Scan Test ...timeout when reading Etc. Check the following items: Note: When one test has been deactivated the phone will be restarted.
SEMC Troubleshooting Manual APPENDIX Troubleshooting Fixture Setup Instructions K850 Troubleshooting Fixture Setup Instructions Insert Memory Card if needed according to picture 10. Front side overview of the TRS Fixture, see Connect Power Supply Channel 1 VBATT picture 1. (Black and Red plugs) according to picture 4.
Page 101
SEMC Troubleshooting Manual APPENDIX Troubleshooting Fixture Setup Instructions K850 Connect FM Radio Cable if needed according to The GND pin on the front side of the TRS picture 13. Fixture can be used as MP TRS Fixture GND or as grounding for the oscilloscope probe, Picture 13 see picture 16.