Extension Fan 1-4 Profile [Standard]
This item allows you to set the appropriate performance level of the CPU fan.
[Standard]
Set to make the CPU fan adjust automatically depending on the CPU
temperature.
[Silent]
Set to minimize the fan speed for quiet CPU fan operation.
[Turbo]
Set to achieve maximum CPU fan speed.
[Manual]
Set to assign the detailed fan speed control parameters.
The following items appear only when you set the Extension Fan Profile to [Manual].
Extension Fan 1-4 Upper Temperature [70]
Use the <+> or <-> keys to adjust the upper limit of the Extension Fan 1-4
temperature. The values range from 20 to 75.
Extension Fan 1-4 Max. Duty Cycle (%) [100]
Use the <+> or <-> keys to adjust the maximum Extension Fan 1-4 duty
cycle. The values range from 20% to 100%. When the CPU temperature
reaches the upper limit, the Extension Fan 1-4 will operate at the maximum
duty cycle.
Extension Fan 1-4 Middle Temperature [45]
Use the <+> or <-> keys to adjust the middle limit of the Extension Fan 1-4
temperature. The values range from 20 to 75.
Extension Fan 1-4 Middle. Duty Cycle (%) [60]
Use the <+> or <-> keys to adjust the maximum Extension Fan 1-4 duty
cycle. The values range from 20% to 100%. When the CPU temperature
reaches the upper limit, the Extension Fan 1-4 will operate at the maximum
duty cycle.
Extension Fan 1-4 Lower Temperature [40]
Use the <+> or <-> keys to adjust the lower limit of the Extension Fan 1-4
temperature. The values range from 20 to 75. The Extension Fan 1-4 will
operate at the minimum duty cycle when the temperature is lower than the
limit.
Extension Fan 1-4 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum Extension Fan 1-4 duty
cycle. The values range from 0% to 100%. When the CPU temperature
is under the limit, the Extension Fan 1-4 will operate at the minimum duty
cycle.
Water Pump Control [Disabled]
[Disabled]
Disable the Water Pump control feature.
[DC mode]
Enable the Water Pump control in DC mode for 3-pin chassis fan.
[PWM mode]
Enable the Water Pump control in PWM mode for 4-pin chassis fan.
The following items appear only when you set the Water Pump Control to [DC mode] or
[PWM mode].
Water Pump Upper Temperature [25]
Use the <+> or <-> keys to adjust the upper limit of the Water Pump
temperature. The values range from 20 to 75.
ASUS Z170-DELUXE Series
3-49