SPECIFICATIONS

Step One
Range:
Repeatability:
Adjustability:
Hysteresis:
Beam width:
Dead band:
LED indication:
Calibration:
Memory:
Supply voltage:
Consumption:
Contact type:
Contact rating:
Contact logic:
Contact fail-safety:
Process temp.:
Temp. comp.:
Electronics temp.:
Pressure:
Enclosure rating:
Enclosure vent:
Encl. material:
Trans. material:
Process mount:
Mount. gasket:
Conduit entrance:
Classification:
CE compliance:
Handling Static-Sensitive Circuits/Devices:
dling the Ultrasonic switch, the technician should follow
these guidelines to reduce any possible electrostatic charge
build-up on the technicians body and the electronic part.
1. Always touch a known good ground source before handling the
part. This should be repeated while handling the part and more
frequently after sitting down from a standing position, sliding
across the seat or walking a distance.
2. Avoid touching electrical terminals of the part unless making connections.
3. DO NOT open the unit cover until it is time to calibrate.
LVCN704: 2" to 4'
(5 cm to 1.2m)
LVCN709: 4" to 9.8'
(10 cm to 3m)
LVCN716: 4" to 16.4'
(10 cm to 5m)
LVCN126: 8" to 26.2'
(20 cm to 8m)
0.25" (6 mm)
Over entire range
LVCN704/709: 0.5" (1.2 cm)
(single set point)
LVCN716/726: 1" (2.5 cm)
(single set point)
LVCN704/709: 2" (5 cm) dia.
LVCN716/726: 3" (7.6 cm) dia.
LVCN704: 2" (5 cm)
LVCN709/716: 4" (10 cm)
LVCN726: 8" (20 cm)
Power, relay and echo status
Target, push button
Non-volatile
AC: 95-250 VAC
DC: 12-28 VDC (Optional)
AC: 20 watts max.
DC: 100 mA @ 24 VDC (Optional)
(3) SPDT relays
60 VA
Single point: alarm
Two point: latching or
out of bounds alarms
Duplex or Alternation:
(Relays 1 and 2 only)
De-energizes during echo signal loss
F: -4° to 140°
C: -20° to 60°
Automatic
F: -40° to 160°
C: -40° to 71°
30 psi (2 bar) @ 25° C., derated @
1.667 psi (.113 bar) per °C. above
25° C.
NEMA 4X (IP65)
Water tight membrane
PC/ABS FR
PVDF Kynar®
LVCN704/709: 1" NPT (1" G)
LVCN716/726: 2" NPT (2" G)
Viton®
Dual, 1/2" NPT
General purpose
EN 61326 EMC
[DC series only (DC powered)]
When han-
LVCN700 Series
Enclosure (Top View)
5.2"
(133 mm)
LVCN704
LVCN709
Enclosure (Side View)
5.2"
(133 mm)
1" NPT
0.75"
(19 mm)
LU75
LU72
LVCN716
LVCN726
Enclosure (Side View)
5.2"
(133 mm)
Temperature/Pressure Derating
40
Unacceptable
Range
30
20
Acceptable
Range
10
00
-40
-20
00
20
40
60
Temperature (C¡)
(1" G)
2" NPT
(2" G)
80