Change Display Intensity Level; Print Request; Output Set; Output Hold - Omega Engineering PTC900 User Manual

Panel-mount programmable timer and real-time clock
Table of Contents

Advertisement

CHANGE DISPLAY INTENSITY LEVEL

When activated (momentary action), the display intensity changes to the next
intensity level (of 4). The four levels correspond to Display Intensity Level
(
) settings of 0, 3, 8 & 15. The intensity level, when changed via the User
Input/Function Key, is not retained at power-down, unless Quick Programming
or Full Programming mode is entered and exited. The unit will power-up at the
last saved intensity level.
Note: The next two parameters only appear when an RS232 or RS485 Serial
Communications Card is installed in the meter.

PRINT REQUEST

When activated, the meter issues a block print through the serial port. The
specific values transmitted during a print request are selected with the Print
Options parameter in Module 7. For User Inputs (level active), the meter
transmits blocks repeatedly as long as the input is active. For Function Keys,
(edge triggered) only one block is transmitted per key press.
PRINT REQUEST and RESET (Edge Triggered)
When activated (momentary action), the meter first issues a block print
through the serial port, and then performs a Momentary Reset on the displays
entered as
in the sublist. The specific values transmitted in the print block
are selected with the Print Options parameter in Module 7. Only one transmit
and reset occurs per User Input activation or Function Key press.
DISPLAY
DESCRIPTION
t-dSp
Cycle Counter
C-dSP
Note: The remaining parameters only appear when a Setpoint Card is
installed in the meter.
OUTPUT HOLD (Level Active)
When active (maintained action), the meter "holds" (maintains) the present
output state for all Setpoints entered as
Output Set and Reset User Inputs. Program only one user input for this function.
DISPLAY
DESCRIPTION
Setpoint 1
SP-1
Setpoint 2
SP-2
SP-3
Setpoint 3
Setpoint 4
SP-4
FACTORY
Timer
NO
NO
in the sublist. Does not apply to
FACTORY
NO
NO
NO
NO
OUTPUT SET (Level Active)
When activated (maintained action), the meter continually activates the
output for all Setpoints entered as
DISPLAY
SP-1
SP-2
SP-3
SP-4
OUTPUT SET (Edge Triggered)
When activated (momentary action), the meter activates the output for all
Setpoints entered as
in the sublist.
DISPLAY
SP-1
SP-2
SP-3
SP-4
OUTPUT RESET (Level Active)
When activated (maintained action), the meter continually deactivates the
output for all Setpoints entered as
DISPLAY
SP-1
SP-2
SP-3
SP-4
OUTPUT RESET (Edge Triggered)
When activated (momentary action), the meter deactivates the output for all
Setpoints entered as
in the sublist.
DISPLAY
SP-1
SP-2
SP-3
SP-4
15
in the sublist.
DESCRIPTION
FACTORY
Setpoint 1
NO
Setpoint 2
NO
Setpoint 3
NO
Setpoint 4
NO
DESCRIPTION
FACTORY
Setpoint 1
NO
Setpoint 2
NO
Setpoint 3
NO
Setpoint 4
NO
in the sublist.
DESCRIPTION
FACTORY
Setpoint 1
NO
Setpoint 2
NO
Setpoint 3
NO
Setpoint 4
NO
DESCRIPTION
FACTORY
Setpoint 1
NO
Setpoint 2
NO
Setpoint 3
NO
Setpoint 4
NO