How to Connect
This is described in the chassis fault finding database in
ComPair.
Figure 5-6 ComPair interface connection
How to Order
ComPair order codes (EU/AP/LATAM):
Starter kit ComPair32/software and ComPair interface
(excl. transformer): 3122 785 90450.
ComPair interface (excl. transformer): 3122 785 90520.
ComPair32 CD (update): 3122 785 60140.
Transformer (non-UK): 4822 727 21632.
Transformer (UK): 4822 727 21633.
ComPair interface cable: 3122 785 90004.
ComPair interface extension cable: 3139 131 03791.
ComPair UART interface cable: 3122 785 90630.
Note: If you encounter any problems, contact your local
support desk.
5.4.2
LVDS Tool
Introduction
This service tool (also called "ComPair Assistant 1") may help
you to identify, in case the TV does not show any picture,
whether the Small Signal Board (SSB) or the display of a Flat
TV is defective.
Furthermore it is possible to program EPLDs with this tool (Byte
blaster). Read the user manual for an explanation of this
feature.
Since 2004, the LVDS output connectors in our Flat TV models
are standardised (with some exceptions). With the two
delivered LVDS interface cables (31p and 20p) you can cover
most chassis (in special cases, an extra cable will be offered).
When operating, the tool will show a small (scaled) picture on
a VGA monitor. Due to a limited memory capacity, it is not
possible to increase the size when processing high-resolution
LVDS signals (> 1280x960). Below this resolution, or when a
DVI monitor is used, the displayed picture will be full size.
Generally this tool is intended to determine if the SSB is
working or not. Thus to determine if LVDS, RGB, and sync
signals are okay.
How to Connect
Connections are explained in the user manual, which is packed
with the tool.
Note: To use the LVDS tool, you must have ComPair release
2004-1 (or later) on your PC (engine version >= 2.2.05).
For every TV type number and screen size, one must choose
the proper settings via ComPair. The ComPair file will be
updated regularly with new introduced chassis information.
Service Modes, Error Codes, and Fault Finding
TO
TO
I 2 C SERVICE
UART SERVICE
CONNECTOR
CONNECTOR
I 2 C
PC
VCR
Power
9V DC
E_06532_021.eps
180804
LC4.31E AA
How to Order
LVDS tool (incl. two LVDS cables: 31p and 20p):
3122 785 90671.
LVDS tool Service Manual:
3122 785 00810.
LVDS cable 31p/FI -> 31p/FI (for JL2.1 chassis):
3122 785 90861.
LVDS cable 30p/DF -> 31p/FI (for LC4.3 chassis):
3122 785 90821.
LVDS cable 41p/FI -> 31p/FI (dual -> single LVDS):
3122 785 90831.
LVDS cable 20p/DF -> 20p/DF (standard with tool):
3122 785 90731.
LVDS cable 31p/FI -> 31p/FI (standard with tool):
3122 785 90662.
LVDS cable 20p/DF -> 20p/DF (for LC4.1 chassis):
3122 785 90851.
5.5

Error Codes

The error code buffer contains all errors detected since the last
time the buffer was erased. The buffer is written from left to
right. When an error occurs that is not yet in the error code
buffer, it is displayed at the left side and all other errors shift one
position to the right.
5.5.1
How to Read the Error Buffer
You can read the error buffer in 3 ways:
On screen via the SAM (if you have a picture).
Examples:
ERROR: 0 0 0 0 0 : No errors detected
ERROR: 6 0 0 0 0 : Error code 6 is the last and only
detected error
ERROR: 9 6 0 0 0 : Error code 6 was detected first and
error code 9 is the last detected (newest) error
Via the blinking LED procedure (when you have no
picture). See "The Blinking LED Procedure".
Via ComPair.
5.5.2
How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
By using the CLEAR command in the SAM menu:
To enter SAM, press the following key sequence on the
remote control transmitter: "062596" directly followed
by the OSD/i+ button (do not allow the display to time
out between entries while keying the sequence).
Make sure the menu item CLEAR is selected. Use the
MENU UP/DOWN buttons, if necessary.
Press the MENU RIGHT button to clear the error
buffer. The text on the right side of the "CLEAR" line will
change from "CLEAR?" to "CLEARED"
If the contents of the error buffer have not changed for 50
hours, the error buffer resets automatically.
Note: If you exit SAM by disconnecting the mains from the
television set, the error buffer is not reset.
5.5.3
Error Codes
In case of non-intermittent faults, write down the errors present
in the error buffer and clear the error buffer before you begin
the repair. This ensures that old error codes are no longer
present.
If possible, check the entire contents of the error buffer. In
some situations, an error code is only the result of another error
and not the actual cause of the problem (for example, a fault in
the protection detection circuitry can also lead to a protection).
5.