Controlling the LCD monitor via RS-232C Remote Control

This LCD monitor can be controlled by connecting a personal computer with a RS-232C terminal.
Functions that can be controlled by a personal computer are:
Power ON or OFF
Switching between input signals
Connection
LCD Monitor + PC
NOTE: If your PC (IBM or IBM compatible) is equipped only with a 25-pin serial port connector, a 25-pin serial port adapter
* RS-232C OUT terminal can connect MDT402S / MDT461S only. Do not connect other equipment.
The following control sequence is used for a single MDT402S / MDT461S. To control multiple MDT402S / MDT461S monitors that
are daisy-chained together please use the extended control command. Instructions for the extended control command can be found
on the CD included with the display. The file is called "External_control_MDT4XXS.pdf". When using the following control
commands, all of the daisy-chained monitors can be controlled at the same time from one monitor. Reply and status commands,
however, will only pertain to the primary monitor, not secondary monitors.
1) Interface
PROTOCOL
BAUD RATE
DATA LENGTH
PARITY BIT
STOP BIT
FLOW CONTROL
This LCD monitor uses RXD, TXD and GND lines for RS-232C control.
2) Control command diagram
The command is structured by the address code, function code, data code and end code. The length of the command is
different for each function.
HEX
ASCII
Downloaded From TV-Manual.com Manuals
PC
RS-232C Cable
is required. Contact your dealer for details.
RS-232C
9600 [bps]
8 [bits]
NONE
1 [bits]
NONE
Address code
Function code
30h 30h
Function
'0' '0'
Function
[Address code]
30h 30h (ASCII code, '0' '0'), fixed.
[Function code]
A code of each fixed control move.
[Data code]
A code of each fixed control data (number) and not always indicated.
[End code]
0Dh (In ASCII code, '
to RS-232C
from RS-232C
"IN" terminal
"OUT" terminal
RS-232C Cable
Data code
End code
Data
0Dh
Data
') fixed.
English-30