NuTone 9412D Installation Instructions Manual

Bulb heaters & bulb heater/fans
Hide thumbs Also See for 9412D:
Table of Contents

Advertisement

Available languages

Available languages

Bulb Heaters & Bulb Heater/Fans
MODELS: 9412D

IMPORTANT SAFETY INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service panel to prevent power from being
switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer's guideline and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Condition-
ing Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Do not install this unit over a tub or shower.
7. Never place a switch where it can be reached from a tub or
shower.
8. Do not operate unit with dimmer switch or speed control.
9. Model 9412D Only: Install housing no closer than 6" from side
wall. For supply connections, use wire suitable for 75°C mini-
mum. Do not install insulation within 3 inches of top or sides of
housing.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in flat ceilings only. DO
NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further information
and requirements.
, 9417DN
(Not Type IC)

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!
, 9422P
(Type IC)
PLAN THE INSTALLATION
Choose the location for your heater. Refer to Warnings and Cautions.
MODELS 9417DN & 9427P ONLY – The unit will operate most
efficiently when located where the shortest possible duct run and
minimum number of elbows will be needed. Units are designed for
use with standard 4" round duct.
Note that two-bulb units (9422P & 9427P) can be fitted with one
infrared bulb (for heat) and one reflector bulb (for light). Dual or multi-
controls can be used for separate control of bulbs and/or exhaust
fan. Purchase controls separately.
Refer to FIGURE 1
Follow these basic steps when installing this unit:
1. Nail unit to joists.
2. Attach ductwork (Models 9417DN or 9427P only).
3. Connect power cable.
4. Fasten grille to housing.
PREPARE THE HEATER
1. Remove the unit from carton. Save carton for use as plaster
shield in rough-in installations.
Refer to FIGURE 2
2. Slide adjustable mounting brackets into bracket channels on
housing.
DAMPER/DUCT
CONNECTOR
CEILING
JOIST
CEILING MATERIAL
, 9427P
(Type IC)
POWER CABLE
HOUSING
GRILLE
BULB(S)
(Type IC)
MOUNTING
BRACKET
FIGURE 1
FIGURE 2

Advertisement

Table of Contents
loading

Summary of Contents for NuTone 9412D

  • Page 1: Installation Instructions

    5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Refer to FIGURE 2 6. Do not install this unit over a tub or shower. 2. Slide adjustable mounting brackets into bracket channels on housing. 7. Never place a switch where it can be reached from a tub or shower. 8. Do not operate unit with dimmer switch or speed control. 9. Model 9412D Only: Install housing no closer than 6” from side POWER CABLE wall. For supply connections, use wire suitable for 75°C mini- MOUNTING DAMPER/DUCT mum. Do not install insulation within 3 inches of top or sides of BRACKET CONNECTOR housing.
  • Page 2 INSTALL THE HEATER Refer to FIGURE 3 1. Position unit between joists and extend mounting brackets. 2. Nail brackets firmly to joists. Bottom of brackets should be po- sitioned flush with joist bottom. Refer to FIGURE 4 3. Brackets are factory-set for ½” thick ceiling material. For thicker ceilings, loosen 4 vertical adjusting screws and lower housing to appropriate thickness on gauges. Tighten vertical adjusting screws firmly. FIGURE 3 ATTACH DUCTWORK (MODELS 9417DN & 9427P ONLY) DAMPER/DUCT CONNECTOR Refer to FIGURE 4 1. Snap the damper/duct connector onto housing. Make sure that tabs on the connector lock in housing slots and that gravity closes damper.
  • Page 3 BLACK BLACK BLACK DUAL CONTROL 120 VAC LINE IN 120 VAC LINE IN 120 VAC LINE IN MODEL 9412D MODEL 9417DN MODEL 9417DN Lamp & Vent operate together Lamp & Vent operate separately BLACK to BLACK, & YELLOW RED to RED...
  • Page 4: Parts List

    BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Page 5 6. No instale la unidad encima de una bañera o ducha. SOPORTE DE DOR/ACOPLE DE 7. Nunca coloque un interruptor en un lugar que pueda ser alcanzado MONTAJE CONDUCTO CASA desde una bañera o ducha. 8. No haga funcionar esta unidad con un variador de luz o control de velocidad. VIGA DEL CIELO 9. Solamente Modelo 9412D: Instale la caja a no menos de 16 cm de RASO la pared lateral. Para conexiones de alimentación, use un alambre apropiado para un mínimo de 75 C. No instale el aislamiento dentro de los 8 cm del tope o los costados de la ca CUIDADO MATERIAL DEL REJILLA BOMBILLA FIGURA 1 . Para uso de ventilación general solamente. No lo use para extraer CIELO RASO materiales o vapores peligrosos o explosivos.
  • Page 6: Uso Y Mantenimiento

    INSTALACION DEL CALENTADOR Refiera a la FIGURA 3 1. Coloque la unidad entre las vigas y extienda los soportes de mon- taje. 2. Clave firmemente los soportes en las vigas. Las partes de abajo de los soportes deben colocarse a nivel con la parte de abajo de la viga. Refiera a la FIGURA 4 3. Los soportes se fijan en fábrica para material de cielo raso de un grosor de 1,3 cm. Para cielo raso más gruesos, afloje 4 tornillos de ajuste vertical y baje la caja al grosor apropiado según los cali- bradores. Atornille firmemente los tornillos de ajuste vertical. FIGURA 3 FIJE LOS CONDUCTOS (MODELOS 9417DN & 9427P SOLAMENTE) ACOPLE DE AMORTIGUADOR/ Refiera a la FIGURA 4 CONDUCTO 1. Enganche el acople de amortiguador/conducto en la caja. Com- pruebe que las orejetas en el acople se enganchen en las ranuras...
  • Page 7 NEGRO CONTROL DE DOS FUNCCIONES LINEA DE ENTRADA 120 VCA LINEA DE ENTRADA 120 VCA LINEA DE ENTRADA 120 VCA MODELO 9412D MODELO 9417DN MODELO 9417DN La lámpara y el ventilador La lámpara y el ventilador funcionan a la vez...
  • Page 8: Lista De Piezas

    Esta garantía le proporciona derechos legales específicos, y usted puede también tener otros derechos, los cuales varían de estado a estado. Esta garantía reemplaza todas las garantías anteriores. Para calificar para la garantía de servicio, usted debe (a) notificar a Broan-NuTone al domicilio o al número de teléfono que se menciona abajo, (b) dar el número del modelo y la identificación de la pieza, y (c) describir la naturaleza de cualquier defecto en el producto o la pieza.

This manual is also suitable for:

9417dn9422p9427p9412d-r019417dn-r019422p-r01 ... Show all

Table of Contents