Delivery Status; Dibos/Divar Pre-Configuration; Raid Settings - Bosch DVA-08E Quick Installation Manual

Raid subsystem
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 69
RAID Subsystem DVA-08E, -08K, -16K
2

Delivery Status

The subsystems are shipped with drives pre-configured for RAID 5. The configuration is
suitable for the most configurations. The factory default settings are shown below.
2.1

DiBos/Divar pre-configuration

2.1.1

RAID Settings

RAID Settings for 500 GB model
Number HDD
RAID Level
Spare Disks
Stripe Size [K]
Partitions
Size of Partition (est.)
Assigned Disk Space
SCSI Channel
SCSI IDs
LUN ID
Table 2.1 DiBos/Divar: Factory default settings DVA-08E/08K/16K (500 GB model)
RAID Settings for 1 TB model
Number HDD
RAID Level
Spare Disks
Stripe Size [K]
Partitions
Size of Partition (est.)
Assigned Disk Space
SCSI Channel
SCSI IDs
LUN ID
Table 2.2 DiBos/Divar: Factory default settings DVA-08E/08K/16K (1 TB model)
Bosch Sicherheitssysteme GmbH
DVA-08E / DVA-08K
4
8
RAID 5
RAID 5
no
no
16
16
1
2
1.5 TB
50 % (1.7 TB)
470000 MB
470000 MB
0
0
0
0, 1
0
0, 0
DVA-08E / DVA-08K
4
8
RAID 5
RAID 5
no
no
16
16
2
4
1.359 TB
1.585 TB
950000 MB
950000 MB
0
0
0, 1
0, 1, 2, 3
0, 0
0, 0, 0, 0
Quick Installation Guide
Delivery Status | en
DVA-16K
8
16
RAID 5
RAID 5
no
no
16
16
2
4
50 % (1.7 TB)
25 % (1.875 TB)
470000 MB
470000 MB
0
0
0, 1
0, 1, 2, 3
0, 0
0, 0, 0, 0
DVA-16K
8
16
RAID 5
RAID 5
no
no
16
16
4
8
1.657 TB
1.699 TB
950000 MB
950000 MB
0
0
0, 0, 0, 0
0, 0, 0, 0, 0, 0,
0, 0
0, 1, 2, 3
0, 1, 2, 3, 4, 5,
6, 7
F.01U.027.800 | V5 | 2010.06
71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dva-08kDva-16k

Table of Contents