■ Remote controller custom code setting
Use the following steps to select the custom code of the remote controller. (Note that the
air conditioner cannot receive a signal if the air conditioner has not been set for the cus-
tom code.)
(1) Press the START/STOP button until only the clock is displayed on the remote control-
ler display.
(2) Press the MODE button for at least 5 seconds to display the current custom code
(initially set to A).
(3) Press the SET TEMP. (▲) (▼) button to change the custom code between
A→B→C→D. Match the code on the display to the air conditioner custom code.
(4) Press the MODE button again to return to the clock display. The custom code will be
changed.
If no buttons are pressed within 30 seconds after the custom code is displayed, the
system returns to the original clock display. In this case, start again from step 1
The air conditioner custom code is set to A prior to shipment.
The remote controller resets to custom code A when the batteries in the remote control-
ler are replaced. If you use a custom code other than custom code A, reset the custom
code after replacing the batteries.
If you do not know the air conditioner custom code setting, try each of the custom codes
(A→B→C→D.) until you find the code which operates the air conditioner.

12. TEST RUN

Do not turn on the power until all installation work is complete.
Always turn on the power 12 hours prior to the start of the operation in order to ensure
compressor protection.
Check items
(1) Is operation of each button on the remote control unit normal?
(2) Does each lamp light normally?
(3) Do air fl ow direction louvers operate normally?
(4) Is the drain normal?
(5) Do not have an abnormal noise and vibration during operation?
• Do not operate the air conditioner in test run for a long time.
[Operation method]
• For the operation method, refer to the operating manual.
• The outdoor unit may not operate depending on the room temperature.
In this case, press the test run button on the remote controller while the air conditioner is
running.
(Point the transmitter section of the remote controller toward the air conditioner and press
the test run button with the tip of a ballpoint pen, etc.)
Transmitter section
TEST RUN button
• To end test operation, press the remote controller START/STOP button.
(When the air conditioner is running by pressing the TEST RUN button, the OPERA-
TION Lamp and TIMER Lamp will simultaneously fl ash slowly.)
WARNING
CAUTION
[Using the wired remote control] (Option)
For the operation method, refer to the operating manual.
(1) Stop the air conditioner operation.
(2) Press the MODE button and the FAN button simultaneously for 2 seconds or more to
start the test run.
(3) Press the START/STOP button to stop the test run.

13. CUSTOMER GUIDANCE

Explain the following to the customer in accordance with the operating manual:
(1) Starting and stopping method, operation switching, temperature adjustment, timer, air
fl ow switching, and other remote control unit operations.
(2) Air fi lter removal and cleaning, and how to use the air louvers.
(3) Give the operating manual to the customer.

14. ERROR CODES

If you use a wireless remote controller, the lamp on the photo detector unit will output error
codes by way of blinking patterns. If you use a wired remote controller, error codes will ap-
pear on the remote control display. See the lamp blinking patterns and error codes in the
table. An error display is displayed only during operation.
Error display
OPERATION
TIMER
ECONOMY
lamp
lamp
lamp
(green)
(orange)
(green)
(1)
(1)
(1)
(2)
(1)
(5)
(2)
(1)
(2)
(2)
(2)
(3)
(2)
(4)
(2)
(7)
(3)
(2)
(3)
(5)
(4)
(1)
(4)
(2)
(5)
(1)
(5)
(3)
(5)
(7)
(5)
(8)
(5)
(15)
(6)
(2)
(6)
(3)
(6)
(4)
(6)
(5)
Test run display
Wired
remote
Description
controller
Error code
Serial communication error
Wired remote controller
communication error
Check run unfinished
Unit number or Refrigerant circuit
address setting error
[Simultaneous Multi]
Indoor unit capacity error
Combination error
• Connection unit number error
(indoor secondary unit)
[Simultaneous Multi]
• Connection unit number error
(indoor unit or branch unit)
[Flexible Multi]
Primary unit, secondary unit set-
up error [Simultaneous Multi]
Indoor unit PCB model
information error
Manual auto switch error
Room temp. sensor error
Indoor unit Heat Ex. Middle temp.
sensor error
Indoor unit fan motor error
Drain pump error
Damper error
Intake grille error
Indoor unit error
Outdoor unit main PCB model
information error or
communication error
Inverter error
Active filter error, PFC circuit er-
ror
Trip terminal L error