Wiring Diagram - North Star M165957K Owner's Manual

Portable, outdoor use-only, gasoline generator 6600 watt continuous (8000 watt surge) capacity
Table of Contents

Advertisement

Diag #
Part #
1
306438
2
31736
3
306422
4
306429
5
306433
6
38191
7
82004
8
82005
9
30643
10
31086
11
31107
12
306604
13
30975
14
82085
15
82155
B23
31106
B24
31108
B26
31109
B28
306599
B29
30660
B31
306601
G22
306603
W25
30977
Wiring Diagram Rev - K
Description
15 Amp, 120 Volt Receptacle (NEMA 5-15R)
20 Amp, 120 Volt Receptacle (NEMA 5-20R)
30 Amp, 120/240 Volt Locking Receptacle
(NEMA L14-30R)
Grounding Post
Thermal Circuit Breaker, 15 Amp
Wiring Harness
(Connects generator to Control Panel)
#8-32 X ½ Button Head Cap Screw
#8-32 Lock Nut
Thermal Circuit Breaker, 20 Amp
Thermal Circuit Breaker, 30 Amp
Wire Assembly (B25, B27)
Wire Assembly (W23, W24, G22, G23, G24)
Control Panel Face
¼ USS Flat Washer
Cable Tie
Black Terminated Wire
Black Terminated Wire
Black Terminated Wire
Black Terminated Wire
Black Terminated Wire
Black Terminated Wire
Green Terminated Wire
White Terminated Wire
40
Qty
1
1
1
1
1
1
6
6
2
2
1
1
1
2
1
1
1
1
1
1
1
1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

165957

Table of Contents