NEC NP-M403X Reference Manual page 57

Control command
Table of Contents

Advertisement

Response
4
When the command succeeds
23h 05h <ID1> <ID2> 10h <DATA01> - <DATA16> <CKS>
Data part
Item
DATA01
DATA02
DATA03
DATA04
DATA05
DATA06
DATA07
DATA08
DATA09
DATA10
DATA11
DATA12
DATA13
DATA14
DATA15
DATA16
4
When the command fails
A3h 05h <ID1> <ID2> 02h <ERR1> <ERR2> <CKS>
Adjusted value status
00h
Display not possible
01h
Adjustment not possible
02h
Adjustment possible
FFh
The specified gain does not exist.
Upper limit of the adjustment range (low-order 8 bits)
Upper limit of the adjustment range (high-order 8 bits)
Lower limit of the adjustment range (low-order 8 bits)
Lower limit of the adjustment range (high-order 8 bits)
Default value (low-order 8 bits)
Default value (high-order 8 bits)
Current value (low-order 8 bits)
Current value (high-order 8 bits)
Wide adjustment width (low-order 8 bits)
Wide adjustment width (high-order 8 bits)
Narrow adjustment width (low-order 8 bits)
Narrow adjustment width (high-order 8 bits)
Whether the default value is valid or invalid
00h
The default value is invalid.
01h
The default value is valid.
Reserved for the system
57
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents