Advertisement

Quick Links

1
Features
A
i t
y
U n
S k
1 B
o o r
1 0 A
- G V
t
l i
I n d
F T X
R - 4
S p
Flat front panel: its stylish appearance blends easily within any
interior décor and is more easy to clean.
Lightweight and compact
Consumes up to 30% less energy than non-inverter units
1
Dual air discharge flow for better air distribution
ECONO mode decreases power consumption so that other
1
appliances that need large power supply can be used
5 steps
1
• Indoor Units • R-410A • FTX-GV1B
standard
• Split Sky Air • Indoor Units
Indoor unit On/Off switch
Indoor unit silent operation
Titanium apatite photocatalytic air purification filter
Anticorrosion treatment of outdoor heat exchanger fin
Powerful mode can be selected for rapid cooling or heating
Energy saving during stand by mode: reduction of energy from 10W
to 2W
optional

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTX-GV1B

  • Page 1 • Indoor Units • R-410A • FTX-GV1B Features o o r - G V 1 0 A I n d F T X R - 4 • Flat front panel: its stylish appearance blends easily within any • Indoor unit On/Off switch interior décor and is more easy to clean.
  • Page 2: For Indoor Units Only

    • Indoor Units • R-410A • FTX-GV1B Specifications FOR INDOOR UNITS ONLY FTX20GV1B FTX25GV1B FTX35GV1B Nominal input Cooling 0.04 0.04 0.04 (Indoor only) Heating 0.04 0.04 0.04 TECHNICAL SPECIFICATIONS FTX20GV1B FTX25GV1B FTX35GV1B Casing Colour White Dimensions Packing Height Width Depth...
  • Page 3: Electrical Specifications

    • Indoor Units • R-410A • FTX-GV1B Specifications TECHNICAL SPECIFICATIONS FTX20GV1B FTX25GV1B FTX35GV1B Cooling Sound Power High Sound High Pressure Medium Silent Operation Heating Sound Power High Sound High Pressure Medium Silent Operation Refrigerant Type R-410A Piping Liquid (OD) Diameter 6.35...
  • Page 4: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • R-410A • FTX-GV1B Dimensional drawing & centre of gravity 3 - 1 Dimensional drawing FTX20-35GV The mark (→) shows piping direction Air flow (Indoor) Rear Right Left Including mounting plate 50Min. 50Min. Front panel fixing screws ( Inside)
  • Page 5: Centre Of Gravity

    • Indoor Units • R-410A • FTX-GV1B Dimensional drawing & centre of gravity 3 - 2 Centre of gravity FTX20-35GV 4D059099 • Split Sky Air • Indoor Units...
  • Page 6: Piping Diagram

    • Indoor Units • R-410A • FTX-GV1B Piping diagram FTX20-35GV INDOOR UNIT Heat exchanger 7.0 Cut 4.8 Cut 7.0 Cut Thermistor on heat exch. 7.0 Cut Cross flow fan Field piping (6.4Cut) Fan motor 9.5 Cut Field piping (9.5Cut) Refrigerant flow...
  • Page 7: Wiring Diagram

    • Indoor Units • R-410A • FTX-GV1B Wiring diagram 5 - 1 Wiring diagram FTX20-35GV FIELD WIRING TRANSMISSION CIRCUIT RECTIFIER OUTDOOR CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again.
  • Page 8: Sound Data

    • Indoor Units • R-410A • FTX-GV1B Sound data 6 - 1 Sound pressure spectrum FTX20GV FTX20GV HEATING COOLING Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz)
  • Page 9 • Indoor Units • R-410A • FTX-GV1B Sound data 6 - 1 Sound pressure spectrum FTX35GV FTX35GV COOLING HEATING Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz)

Table of Contents