TECHNICAL DATA

Mains
Current:
Installation
Controls
Power Consumption High blower speed: 20 watts
Airflow rates
Ionization
Total negative ion output:
12
2.5 x 10
= 2.5 billion negative ions per second.
Minimum of 1000 negative air ions per cm
Ionization voltage:
Ionization voltage has been optimally selected. It will provide an ample supply of negative
ions in the room and at the same time minimize deposits of pollutants in the immediate
vicinity of the unit.
Short current to ground is less than 0.1 milliamperes.
Direct contact with the carbon ionizing filament is completely safe.
Ionoscope
Ozone
Effective range
Dimensions
Net Weight
Safety
Complies with strictest standards: British Electrical Safety Standard BS3456 (UK), UL (USA)
and GS (Germany).
EEC Directives
Meets EEC directive 93/68/EEC (EMC) on electro-magnetic
compatibility and EEC directive 73/23/EEC (LVD) on safety.
* Suject to change without notification
230-240 V / 50 Hz / 20 W
0,17 Amps
No installation required.
Plugs into any electrical outlet.
Control switch:
Off / high speed with ionization
/ low speed with ionization.
When the light goes on, the
unit is in operation.
Low blower speed: 12 watts
3
High speed: 85 m
/h
3
Low speed: 50 m
/h
3
6kV
Ion detector is provided with the unit.
50% lower than UL safety limits.
up to 6 meters
2
Coverage 24 m
Length: 284 mm
Width: 227 mm
Height: 150 mm
1.4 kg
in an area of 4 m x 6 m (= 24 m