2. IDLE PERIODS

If the appliance is not going to be used for some time, take
the following precautions:
• Close cocks or main switches ahead of the appliance.
• Go over all stainless-steel surfaces vigorously with a cloth
moistened with paraffin oil in order to create a protective
film.
• Periodically air the premises.
• Have the appliance checked before using it again.
• To prevent too rapid evaporation of accumulated moisture
with consequent breakage of elements, switch electrical
appliances on at minimum heat for at least 45 minutes
before reuse.

3. INTERNAL PARTS

IMPORTANT! Operations to be carried out only by
specialised technicians.
• Check the condition of internal parts.
• Remove any deposits of grime inside the appliance.
• Check and clean the discharge system.
• Remove the 4 screws "V" and back "S" to access the inner
rear part of the appliance.
V
NOTE ! In particular conditions (e.g. intensive appliance
use, salty environment, etc.) the above-mentioned cleaning
should be more frequent.
(every 6 months)
S
VIII MAINTENANCE

1. MAINTENANCE

All the components requiring maintenance are accessible
from the front of the appliance, after removing the control
panel and front panel. Disconnect the power supply before
opening the appliance
1.1 BRIEF TROUBLESHOOTING GUIDE
Even with normal use, malfunctions can occur.
-
The pilot burner of open rings does not light
Possible causes:
Insufficient pressure in gas pipes.
Incorrect cock adjustment
Faulty gas cock.
-
The oven pilot burner does not light
Possible causes:
Insufficient pressure in gas pipes
Blocked nozzle
Faulty gas valve
-
The pilot burner goes out when the igniter knob is released
Possible causes:
The pilot burner is not heating the thermocouple enough.
Faulty thermocouple.
The gas cock knob is not being pressed properly.
Lack of gas pressure at cock.
Faulty gas cock or gas valve.
-
The pilot burner is still lit but the main burner does not
light
Possible causes:
Loss of pressure in gas pipe.
Thermopile faulty or not heated enough by the pilot flame.
Blocked nozzle or faulty gas cock or valve.
Burner with gas outlet holes clogged.
Faulty thermopile.
Faulty electrical system contacts.
Faulty thermostat.
-
The oven temperature cannot be adjusted.
Possible causes:
Faulty gas cock or gas valve.
Faulty electric thermostat.
Faulty electrical system contacts.
1.2 MAINTENANCE SCHEDULE
It is advisable to have the appliance inspected by an
authorised person at least every 12 months. For this
purpose, it is advisable to stipulate a servicing contract.