OU TD OO R PC B C I RCUI T DIAG RAM
INVERTER ASSEMBLY
EZ-0122DHUE
TERMINAL
TO OUTDOOR UNIT
L
1
N
2
SERIAL
3
POWER
4
SOURCE
5
EARTH
WIRE w/TERMINAL
( CORE )
1015#22
GREEN
EMI FILTER
2013.04.01
EMI FILTER
EMI FILTER
UL1015
AWG20
BLACK
UL1015
AWG20
WHITE
UL1015
AWG20
RED
UL1015
AWG14
BLACK
UL1015
AWG14
WHITE
UL1015
AWG16
GREEN
THERMISTOR ( PIPE TEMP. )
BLACK
BLACK
BLACK
BLACK
THERMISTOR
( DISCHARGE TEMP. )
FRAME
FRAME
THERMISTOR
( OUTDOOR TEMP. )
BLACK
BLACK
REACTOR
15mH, 10A
W101
B
W102
B
UL3271
W4
AWG14
B
WHITE
W1
B
W2
B
W3
W10
B
B
1
CN71
2
B04B-PL I RK-1
3
RED
4
MAIN PCB
K10BO-120LHUE-C1
1
CN70
2
B03B-PL I RK-1
WHITE
3
www
UL3271
AWG14
RED
W11
B
B5 ( 7-2.3 ) B-XASK-1-A
B05B-PL I RK-1
COMPRESSOR
UL3271
AWG16
W7
RED
U
B
UL3271
AWG16
W8
WHITE
V
B
UL3271
AWG16
W9
BLACK
W
B
CN30
2-1747052-3
1
4-WAY VALVE
BLACK
or
2
BLACK
1747052-1
BLUE or WHITE
1
DC FAN MOTOR
RED
2
3
CN800
4
F M
BLACK
WHITE
5
WHITE
6
YELLOW
7
BROWN or BLUE
1
RED
2
BLUE
CN40
EXPANSION
M
3
ORANGE
VALVE
WHITE
4
YELLOW
5
WHITE
M