Level 3 Repair
Ear MIC Working
Operate MIC
NG
Pollute
MIC Hole?
NO
Check C508,
C511, C512
YES
Check
Mic_Bias(L500)
YES
Change Earphone
YES
NO
NO
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
Clean up
MIC hole
Resoldering
C508, C511, C512
Resoldering C504 or U635,
L505, C507, C514 And If Mic_Bias
is low, Resoldering or Replace
8-26