CIRCUIT DESCRIPTION

12-7) DAMPER CIRCUIT

1) The temperature of R-room is controlled by opening and closing of damper with stepping motor, supplying &
blocking cold air.
2) TA7774P (IC07) operates the damper. TA7774P is the driver IC only for step motor. If the regular signal is
provided to TA7774P from Micom, send combined signal to Quad-Polar step motor to rotate on certain
direction. This makes clockwise or counter clockwise rotation to make the damper open or close.
3) Since the damper always touches the cold air, DC 12V/1W heater is installed, always on to prevent the
malfunction from moisture and is controlled on conditions. (Operation conditions can be changed). Micon #15
pin connected to IC4 controls the damper heater like category 3.