Selecting Installation Site And Air Flow Direction - Daikin FUY71FJV1 Installation Manual

Split system
Hide thumbs Also See for FUY71FJV1:
Table of Contents

Advertisement

The unit may malfunction
Is wiring size according
or the components burn
to specifications?
out.
Is something blocking
the air outlet or inlet of
It may result in insuffi-
either the indoor or out-
cient cooling.
door units?
Are refrigerant piping
length and additional
The refrigerant charge in
refrigerant charge noted
the system is not clear.
down?
2. Items to be checked at time of delivery
∗Also review the "SAFETY PRECAUTIONS"
Items to be checked
Did you explain about operations while showing the
instruction manual to your customer?
Did you hand the instruction manual over to your
customer?
Points for explanation about operations
The items with
WARNING and
the instruction manual are the items pertaining to possi-
bilities for bodily injury and material damage in addition
to the general usage of the product. Accordingly, it is
necessary that you make a full explanation about the
described contents and also ask your customers to read
the instruction manual.
2-4 NOTE TO THE INSTALLER
Be sure to instruct customers how to properly operate the unit
(especially cleaning filters, operating different functions, and
adjusting the temperature) by having them carry out operations
themselves while looking at the manual.
3.
SELECTING INSTALLATION SITE
AND AIR FLOW DIRECTION
3-1 Select an installation site where the following
conditions are fulfilled and that meets your
customer's approval.
• In the upper space (including the back of the ceiling) of the
indoor unit where there is no possible dripping of water
from the refrigerant pipe, drain pipe, water pipe, etc.
• Where optimum air distribution can be ensured.
• Where nothing blocks air passage.
• Where condensate can be properly drained.
• Where the ceiling is strong enough to bear the indoor
unit weight.
• Where the false ceiling is not noticeably on an incline.
• Where sufficient clearance for maintenance and service
can be ensured.
• Where there is no risk of flammable gas leakage.
• Where piping between indoor and outdoor units is pos-
sible within the allowable limit.
(Refer to the installation manual for the outdoor unit.)
[CAUTION]
Only use the included parts or parts which match the speci-
fications when installing the unit.
3
Check
CAUTION marks in
• Install the indoor unit no less than 2.5m above the floor.
Where unavoidably lower, take what measures are nec-
essary to keep hands out of the air outlet.
Space required for installation
Air discharge
≥ 1500
Floor
Air
discharge
≥ 1500
Floor
** Space is required to attach/detach corner covers.
3-2 Air flow direction
Select the air flow direction that best suits the unit's location. 2-
way and 3-way air flow must be set from the remote controller.
For details, see FIELD SETTING.
NOTE
• Restrictions are placed on piping direction, therefore select
flow direction from the below patterns.
[Air flow patterns] (Refer to Fig. 1)
(IIlustrations seen from ceiling)
A, B, C and D indicate drain pans.
Air flow
C
direction
B
D
A
4-way air
discharge
C
D
2-way air
discharge
Refrigerant pipe direction
To the rear (Straight pipe)
To the right (Elbow required)
Upward running refrigerant pipes are possible in all patterns.
3-3 Use suspension bolts for installation. Check
whether the ceiling is strong enough to support
the weight of the unit or not. If there is a risk,
reinforce the ceiling before installing the unit.
(Installation pitch is marked on the paper pattern for
installation. Refer to it to check for points requiring rein-
forcing.)
Air discharge
Air inlet
≥ 1500
Obstruction
Air inlet
≥ 30∗∗
Obstruction
C
D
B
D
C
A
3-way air
3-way air
discharge
discharge
Optional parts required
(Back-to-back blocking pad kit)
C
A
2-way air
discharge
Fig. 1
English