20.5 Auto Standby Time Read

This command is used in order to read the setting of Auto Standby Time.
1) The controller requests the monitor to reply Time setting.
Header
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'8'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h,38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'B' (43h, 41h, 30h, 42h): Power Save Mode command
'0'-'4' (30h, 30h): Auto Standby Time Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Time to the controller.
Header
SOH-'0'-'0'-Monitor ID-
'B'-'0'-'A'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', replying monitor's ID is '1'.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'B' (43h, 42h, 30h, 42h): Power Save Mode Reply
'0'-'4' (30h, 34h): Auto Standby Time Read
TIME: AUTO STANDBY TIME (sec.)
00h (30h, 30h) – 78h (37h, 38h): 1 (5dec.) – 120 (600sec.)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Message
STX-'C'-'A'-'0'-'B'-'0'-'4'-ETX
STX-'C'-'B'-'0'-'B'-'0'-'4'-TIME-ETX
(116/139)
Check code
BCC
Message
Delimiter
CR
Check code
Delimiter
BCC
CR