Error Items
1 I/M-SENSOR
2 R-SENSOR
DEFROST
3
SENSOR OF R
ROOM
4 R-FAN ERROR
I/M FUNCTION
5
ERROR
COOL SELECT
6
ZONE SENSOR
R-DEFROSTING
7
ERROR
PANTRY-DAMPER-
8
HEATER ERROR
CR-SENSOR
9
4-Door
PANTRY-SENSOR
9
ERROR
DEFROST
10
SENSOR OF CR
ROOM 4-Door
DEFROST
DEFROST
11
SENSOR OF CF
ROOM 4-Door
CR-DEFROSTING
12
ERROR 4-Door
CF-DEFROSTING
13
ERROR 4-Door
WATER HEATER
14
ERROR
Samsung 'Refrigerator' Diagnostic Code Quick Guide
LED
Ice Maker Sensor Error- This can be an Electric wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
Refrigerator Compartment Sensor Error- This can be an Electric wire
cut, short-circuit, contact failure, or missing sensor. Cause is also a
temperature reading > 122°or < -58 ° F.
Ref. Defrost Sensor Error- This can be an Electric wire cut, short-circuit,
contact failure, or missing sensor. Cause is also a temperature reading >
122°or < -58 ° F.
This error indicates the Refrigerator Evap Fan is not spinning at the
correct RPM or the fan feedback line is open.
This error indicates the Ice tray has not returned to level after an ice
harvest. The error is displayed after three failed attempts.
Cool Select Zone Sensor Error- This can be an Electric wire cut, short-
circuit, contact failure, or missing sensor. Cause is also a temperature
reading > 122°or < -58 ° F.
Refrigerator Room defrost heater- wire cut, short-circuit, contact failure,
missing sensor housing, or defective temperature fuse/bi-metal. Defrost
on for over 80 minutes
Sensor system in Pantry Room errors
CR Compartment Sensor Error- This can be an Electric wire cut, short-
circuit, contact failure, or missing sensor. Cause is also a temperature
reading > 122°or < -58 ° F.
CR Compartment Sensor Error- This can be an Electric wire cut, short-
circuit, contact failure, or missing sensor. Cause is also a temperature
reading > 122°or < -58 ° F.
CR Compartment Defrost Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
CF Compartment Defrost Sensor Error- This can be a wire cut, short-
CF Compartment Defrost Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
CR Compartment Defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
Defrost on for over 80 minutes
CF Compartment defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
Defrost on for over 80 minutes
Error is displayed when the water reservoir tank heater is open or shorted