Hitachi VK-S454R Service Manual page 26

Hide thumbs Also See for VK-S454R:
Table of Contents

Advertisement

Troubleshooting > Trouble Diagnosis
(6) No focus lens operation
Does zoom
NG
operate
normally?
OK
When power turned
NG
on: PG1301-12
(TL1336): Pulse
OK
PG1301-19 to 22
OK
(TL1347 to1350):
Pulses
NG
NG
IC1302-2,4,24: 3V
OK
NG
IC1302-10,15: 7.2V
OK
IC1201-9
NG
(TL1312):
Pulse
OK
NG
IC1302-23: Pulse
OK
NG
IC1302-20: Pulse
OK
NG
IC1302-5: Pulse
OK
IC1302 faulty.
The test lands and components of circuit no. 1000-1099 are
on the SP circuit board.
The test lands and components of circuit no. 1100-1499 are
See "(4)No zoom and
on the PC circuit board.
focus operation."
The test lands and components of circuit no. 1500 and higher
are on the CSR circuit board.
Lens unit faulty.
Check the 3V line
Check the 7.2V (VM)
line
IC1201 faulty.
IC1201 faulty.
IC1201 faulty.
IC1201 faulty.
C h e c k t h e
NG
c o n n e c t i o n s o f t h e
l e n s f l a t c a b l e .
OK
P G 1 3 0 1 - 1
NG
C h e c k t h e 3 V l i n e
( T L 1 3 4 6 ) :
3 V
OK
P G 1 3 0 1 - 1 4
NG
( T L 1 3 4 4 ) :
P u l s e
OK
L e n s u n i t f a u l t y .
4 - 7
C o r r e c t t h e
c o n n e c t i o n s
o f t h e f l a t c a b l e .
I C 1 2 0 1 f a u l t y .
R 1 2 0 4 f a u l t y .
Q 1 2 0 1 f a u l t y .

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vk-s454er

Table of Contents