I. Gas Log/Lighter Provision
WARNING! Fire and/or Asphyxiation Risk!
solid wood fuel or decorative gas appliance only. Gas fi re
generates fumes.
DO NOT install unvented gas logs
Damper must be locked fully open when gas logs are
installed
A certifi ed gas log lighter or decorative gas log set can be
installed in this fi replace.
Maximum input is 150,000 BTU/hr.
Decorative gas appliance must be certifi ed to ANSI
Z21.60 "Standard for Decorative Gas Appliances for
Installation in Vented Fireplaces".
Must be installed in accordance with the National Fuel
Gas Code, ANSI Z223.1.
A gas log set must incorporate a gas shutoff.
Gas log set requires the damper to be locked fully open.
Knockouts are provided on both sides of the fi replace
for 1/2 in. (13 mm) iron pipe.
A locating dimple (Figure 8.5) is located on on both sides
of the fi replace in the molded brick panels for drilling a
1 in. (25 mm) diameter hole for installation of a gas line.
After the panel is installed, drill the hole for the gas line.
Seal panel around pipe with fi replace mortar or a non-
combustible sealant.
J. Wood Burning Inserts
WARNING! Risk of Fire!
serts may cause fi replace or chimney system to overheat.
If a wood burning insert is being installed in this fi replace,
Hearth & Home Technologies recommends full reline of
the chimney.
Cooling air openings at the top of the chimney must not
be obstructed in any manner.
Hearth & Home Technologies recommends securing the
reline at the top of the fl ue and using the cap certifi ed for
use with this fi replace system.
Heatilator • Birmingham 42-B Installation Manual • 4059-715 • Rev C • 2/14/13
Use with
Improper installation of wood in-
Firebox
Refractory
Seal with
fireplace mortar
or non-combust-
ible sealant
Gas line
Gas line
Repack
insulation
knockout
4 in.
(102 mm)
Figure 8.4
Gas Line Installation
Gas Line
Dimple
Gas Line
Dimple
Figure 8.5
Gas Line Dimples
Outer shell
of fireplace
Maintain air clearance
to combustibles.
Combustible
materials
1 1/2 in. (38 mm)
air space around
pipe
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
37