NEC DLP CINEMA NC1600C User Manual page 52

Nec projector user manual
Hide thumbs Also See for DLP CINEMA NC1600C:
Table of Contents

Advertisement

6. Appendix
Input Connector
Voltage applied across the pins of Ext_GPIN_P and
Ext_GPIN_N should be in the range from 3.3 Vdc to 10 Vdc.
Recommended Operating Current: 5mA
Absolute Maximum Rating:
• Using GPIO Control
Momentary "ON" pulse enables you to control projector. To enable "ON" pulse, hold it for at least 500 ms. Hold "OFF" for at least
500 ms before "ON". (See page 53)
Here is function list to control projector by using GPIO port.
Pin No.
Photo-coupler ON/OFF
1-20
2-21
3-22
4-23
4-23
ON
3-22
5-24
5-24
ON
3-22
6-25
4-23
OFF
5-24
OFF
6-25
OFF
OFF
ON
ON
ON
ON
Example for dousing image:
Example for selecting Macro 2:
NOTE
• The operation command coming from GPI/O port will be canceled when the projector is processing other
tasks, such as lamp cooling and switching title.
• Set all other pins than those in use to "OFF".
• The operation command is executed upon continuous input of the "ON" pulse for approximately 200 ms.
52
GP I/O Connector
Ext_GPIN_P
Pin No.:
1
2
3
4
23mA
Ext_GPIN_N
Pin No.:
20 21 22 23 24 25 26
ON
ON
3-22
OFF
3-22
OFF
5-24
4-23
3-22
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
4-23 is pulsed with keeping 3-22 off.
3-22 and 4-23 are pulsed simultaneously with keeping 6-25 and 5-24 off.
Inside Projector
Resist = 390 Ω
5
6
7
8
27
Lamp on
Lamp off
-
Image doused
-
Image un-doused
-
Selects title registered to MACRO 1
Selects title registered to MACRO 2
Selects title registered to MACRO 3
Selects title registered to MACRO 4
Selects title registered to MACRO 5
Selects title registered to MACRO 6
Selects title registered to MACRO 7
Selects title registered to MACRO 8
Photo-coupler
Forward direction voltage: 1.1V (@5mA)
Function

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents