Replacement Of Air Filter; Replacement Of High Voltage Capacitor - Samsung CM1929 Service Manual

Table of Contents

Advertisement

4. Disassembly and Reassembly

4-10 Replacement of Air Filter

1 . Remove the bolt at both ends of the Air Filter . Then
the locking clamps inside are released .
2 . Lift the Air Filter off the post carefully .
NOTE : Spacer pins are not detachable from the
Air Filter

4-11 Replacement of High Voltage Capacitor

NOTE: It is not necessary to remove Magnetron in
order to remove HVC .
1 . Remove the outer panel and back cover .
2 . Discharge the high voltage capacitor .
3 . Remove HVT wire and H .V .Fuse .
4 . Remove screws securing HVC bracket .
14
Bolt
H.V.Capacitor