2.4 Alarms Displayed While Armed Option

You can disable the display of alarms on the keypad when the system is armed. The
display of alarms is enabled by default. To disable the display of alarms when the
system is armed, turn off section [6], option [5]:
1. Enter [*][8][Installer's code]
2. Enter [000] to go to keypad programming
3. To turn the display of alarms on or off, enter section [6].
4. Turn option [5] on or off:
[5]
ON = Alarms not displayed while system is armed
OFF = Alarms are always displayed while system is armed
5. When you are finished, press [#] to exit.

2.5 Emergency (Fire, Auxiliary, Panic) Key Options

You can enable or disable the Fire, Auxiliary and Panic keys at each keypad. These
keys are enabled by default. Please see your system's Installation Manual for more
information on these keys and their options. To turn any of the emergency keys on or
off on the keypad:
1. Enter [*][8][Installer's code]
2. Enter [000] to go to keypad programming
3. Enter section [7].
4. To turn the emergency key options on or off, press [1], [2], or [3]:
[1]
ON = Fire key enabled
OFF = Fire key disabled
[2]
ON = Auxiliary key enabled
OFF = Auxiliary key disabled
[3]
ON = Panic key enabled
OFF = Panic key disabled
5. When you are finished, press [#] to exit.

2.6 Door Chime Options

You can program the LCD5501Z32-433 keypad to sound a tone when any zone is
opened or closed. There are two parts to the LCD5501Z32-433 door chime
programming:
• Program if the LCD5501Z32-433 will chime when zones are opened and/or closed.
• Program the type of sound the LCD5501Z32-433 will make when an individual zone is
opened or closed.
For the door chime feature to work, you will also need to turn on the Door Chime
attribute for each zone that will trigger the chime. This programming is done in the
control panel software. Refer to your control panel's Installation Manual for more
information.
Door Chime on Zone Openings/Closings
You can program each LCD5501Z32-433 keypad to sound a door chime when zones are
opened and/or when they are closed. By default, LCD5501Z32-433 keypads are
programmed to sound door chimes on both zone openings and closings.
To change the door chime opening/closing settings, at each LCD5501Z32-433
keypad: