Circuit Protections

This projector provides the following circuit protections to operate in safety. If the abnormality occurs inside the pro-
jector, it will automatically turn off by operating one of the following protection circuits.

Thermal switch

There is the thermal switch (SW90) inside of the projector to detect
the internal temperature rising abnormally. When the internal tem-
perature reaches near 105˚C, the thermal switch opens to stop the
operation of the power supply circuit.
The thermal switch cannot be reset itself automatically even if the
internal temperature becomes normal. Reset the thermal switch
following to the below procedure.
How to reset the thermal switch
1. Remove the cabinet top, cabinet front and main board and then
remove the power box top cover.
. Press the reset button on the thermal switch in the power box.
CAUtIoN:
Before press the reset button, make sure that the AC cord must be
disconnected from the AC outlet.

Lamp cover switch

The lamp cover switch (SW901) cuts off the drive signal to the lamp
circuit when the lamp cover is removed or not closed completely.
After opening the lamp cover for replacing the lamp ass'y, place the
lamp cover correctly otherwise the projector can not turn on.

Fuse

A fuse is located inside of the projector. When the POWER indica-
tor is not lightning, the fuse may be opened. Check the fuse as
following steps.
The fuse should be used with the following type;
Fuse Part No.: 323 021 7804
tYPE t6.3AH 250V FUSE
LIttLE FUSE INC. tYPE 21506.3
How to replace the fuse
1. Remove the lamp cover and fuse cover as shown in figure.
. Take the fuse out from the aperture, and replace the new one
with the specified type.
Fuse cover
Fuse
-5-
Thermal switch (SW90)